    Explosion-proof type vortex flowmeter

    5防爆型渦街流量計(ji).png
    • 5防爆型渦街流量計(ji).png
    Explosion-proof type vortex flowmeter is according to the principle of Carmen (Karman vortex street …

    Description:

    Products overview:
    ZW - LUGB seriesExplosion-proof type vortex flowmeterIs using the liquid vibration principle and development of a new type of flowmeter, widely used in petroleum, chemical industry, metallurgy, paper and other fluid measurement.The flowmeter have no moving parts, high reliability, high precision, long life, can be in a very wide range of flow measuring precise instantaneous flow and cumulative flow of liquid.It is not affected by medium, the influence of temperature, pressure, viscosity and component without plugging, BuKa, not easy to scale formation, corrosion resistance, high temperature, high pressure safety explosion-proof, suitable for bad environment.Traffic integration of scoring display and remote transmission, and can output pulse signals or electric current signal and computer networking.
    Second, the measuring principle:
    ZW - LUGB seriesExplosion-proof type vortex flowmeter is by the design, testing probe in the flow field in the vortex body and the corresponding electronic circuit, etc.When the fluid flows through the spiral body occurs, it is formed on both sides of the two rows of vortex variations, this vortex is known as the karman vortex street.On the basis of the theory of karman vortex street and proposed the karman vortex street frequency is proportional to the velocity of the fluid, the relation between the frequency and velocity are presented:
    F = St * V/d type:
    F vortex frequency (Hz)
    V vortex occurred body on both sides of the average flow velocity (m/s)
    St, luo hall coefficient (constant)
    These variations of vortex is formed a series of variations of negative pressure, the pressure on detecting probe, and produce a series of alternating electric signals, after dealing with the preamplifier conversion, plastic, amplification, the output is proportional to the vortex synchronous pulse frequency signal (or standard).
    Third, selection and application of use:
    1, in order to use convenient, battery type USES the micro power consumption of new and high technology, using lithium batteries don't run around more than a year, saving the purchase cost of installation, cable and display instrument to local display instantaneous flow and cumulative flow, etc.
    2, temperature compensation, a body with a temperature sensor, can directly measure the temperature of saturated steam and calculate the stress, which shows that the mass flow of saturated steam.
    3 size, temperature, pressure compensation with temperature and pressure sensors, used for gas flow measurement can directly measure the temperature and pressure of gas medium, showing the state of the volume of the gas flow.
    4, widely used in petroleum, chemical industry, metallurgy, machinery, paper, and the city pipe heating, water supply, gas and other industries of all kinds of low viscosity liquid, gas, steam, etc of single-phase fluid process measurement and energy saving management.
    Four, the main features:
    1, can accurately measure within wide flow range of gas, liquid and steam flow and not affected by fluid physical properties;
    2, not affected by temperature, pressure, not easy to plug at the same time, not easy card, not easy to scale, high temperature resistant, high voltage;
    3, safety explosion-proof, suitable for bad environment;
    4, have no moving parts, no hole aperture design, product without any abrasion, corrosion resistance, dirt without mechanical maintenance, long service life;
    5, using micro power consumption of new and high technology, a battery-powered scene shows type flowmeter, power is not running for more than two years;
    6, temperature, pressure compensation integrated design;
    7, current output are electrical isolation, good common-mode interference suppression ability;
    8, also showed flow values and cumulative flow value, don't have to take turns to switch;
    9, using vibration probe, the effective elimination of the influence of external vibration;
    10, using split type signal converters, cable zui, 100 meters long;
    11, than a wide range of those days;
    12, instrument structure design is reasonable, wide dynamic range, small pressure loss;
    13, table body is made of stainless steel material, can be applied to measurements of corrosive medium;
    14, the liquid crystal display, pulse, 4 ~ 20 ma output 485 newsletter, or can be connected to the industrial automation system.
    Five, the technical parameters:
    1, the measured medium: liquid, gas, steam;
    2, measuring range: (see table below);
    3: (see table), nominal size of non-standard products can be customized according to user requirements special;
    4, temperature range: piezoelectric - 40 ℃ ~ 350 ℃ capacitive - 60 ℃ ~ 450 ℃;
    5, pressure specifications: PN1.6 Mpa;PN2.5 Mpa;Specifications can be customized special PN4.0 Mpa, higher pressure;
    6, fan surrounded degree: normal range "extended range 1:15;
    7, the pressure loss coefficient: Cd 2.6 or less;
    8, system measuring accuracy: liquid, gas, plus or minus 1% of the value;
    Steam steamed value plus or minus 1.5%;
    Insert the value plus or minus 2.5%;
    9, the power supply voltage: sensor + 12 VDC and + 24 VDC (optional) transmitter + 24 VDC;
    Site type display instrument with 3.6 V lithium batteries;
    10, output signal, sensor pulse frequency signal 0.1 ~ 3000 hz low level 1 v high level 6 v or more or less;
    . Transducer two wire system 4 ~ 20 ma DC current signal;
    11, allows vibration acceleration: piezoelectric capacitive acuities were 1.0 g 0.2 g or less;
    : 12, the environment temperature sensors: - 30 ℃ ~ 65 ℃ transmitter, scene shows: - 10 ℃ to 50 ℃.
    13, environment humidity: 5 ~ 85% relative humidity;
    14 and the atmospheric pressure: 86 ~ 106 kpa;
    15, signal remote transmission distance: 500 m or less.
    16, signal interface: internal thread M20 x 1.5;
    17, explosion-proof grade: (ia) Ⅱ CT2 - T5;
    18, protection grade: regular IP65 diving IP68;
    19, instrument material: instrument shell adopts aluminium alloy, the table body part adopts 304 stainless steel material, also can according to user requirements the use of special materials.
    Six, installation requirements:
    1, the vortex street only one-way measurement, pay attention to when installation to ensure medium flow direction and flow meter in the same direction indicated by an arrow.
    2, installation for the vertical installation, medium from bottom to top through the flow meter.The flow meter installed in vertical pipe runs, from bottom to top direction of flow.
    When mounted horizontally, and 3 meter must be installed in the high of the whole system, and to ensure that the outlet pressure corresponding;Do not install in pipeline zui high, because of zui highs tend to gas accumulation, the pipe is not full, export direct vent.
    4, when measuring high temperature fluid, used in a vertical installations as far as possible;If have to horizontal installation, please send the flow transmitter partial vertical downward, or horizontal lateral loading, avoid high temperature;Pay attention to the installation location of air flow or well ventilated.
    5, straight pipe requirements: at least ensure before 15 times the pipe diameter, flow meter after 5 times the pipe diameter.Before such as flowmeter bend, indentation, expand the interference sources, such as need to ensure before 30 to 40 times the pipe diameter, flow meter after six times the pipe diameter.Flow meter should be installed in regulating valve, pressure or temperature sensors upstream.
    6, when installation, pay attention to the pipe size should be slightly bigger than or equal to the inner diameter of the instrument.
    7, the use of seals, pay attention to the sealing ring inside diameter should be slightly greater than or equal to the inner diameter of the instrument, sealing ring center located in the heart of the pipeline.
    8, cable entry seal instrument electric connection, must pay attention to in line hole sealing.Must choose according to meter cable entry model corresponding sealing interface (M20 Χ 1.5;1/2 "NPT.G1/2 '), and properly, closely installation.No seal joint, or careless, can not meet the sealing effect.

    Seven, appearance size:

    DN

    A

    B

    C

    D

    15

    90

    Φ 57

    383

    45

    20

    100

    Φ 57

    388

    50

    25

    100

    Φ 57

    394

    50

    32

    100

    Φ 65

    396

    50

    40

    100

    Φ 75

    401

    50

    50

    110

    Φ 87

    407

    55

    65

    110

    Φ 109

    418

    55

    80

    110

    Φ 120

    423

    55

    100

    120

    Φ 149

    447

    60

    125

    125

    Φ 175

    474

    65

    150

    145

    Φ 203

    501

    75

    200

    170

    Φ 259

    556

    100

    250

    190

    Φ 312

    608

    120

    300

    210

    Φ 363

    660

    140

    350

    230

    Φ 409

    709

    160

    400

    250

    Φ 460

    756

    180

    450

    275

    Φ 520

    814

    205

    500

    290

    Φ 575

    869

    225

    Eight, pipe requirements:
    1, the requirement for straight pipe:
    In order to ensure that the instrument, accurate to run normally, sensor must have a certain straight pipe upstream and downstream of the installation points, to adjust the flow field, as shown.

    Figure 1: concentric contraction tube;
    Figure 2: the concentric expansion tube;
    Figure 3: a 90 - degree Angle;
    Figure 4: the same plane of two 90 - degree Angle;
    Figure 5: different plane of two 90 - degree Angle;
    Figure 6: regulating valve should be installed downstream of the sensor in 5 d to the distance, if the sensor must be installed in the upstream, the sensors should be not less than 50 d upstream, straight pipe section downstream straight pipe section should be not less than 5 d.
    2, the requirement of pipe:
    A, upstream and downstream piping diameter D and the same as the sensor inner diameter DN, its difference satisfy the following conditions: 0.95 DN D 1.1 or less or less DN.
    B, piping shall be concentric with sensor, coaxial degree should be less than 0.05 DN.
    C, gasket not protruding into the pipe, the inner diameter slightly larger than sensors.
    D, if you want to stop inspection and cleaning the sensor, the by-pass pipe should be set up,As shown in the figure below.

     
    3, the requirement of pipe vibration:
    Sensors to avoid installed on the strong pipeline vibration, if necessary to install, shock absorption measures must be taken, respectively at the upstream and downstream of sensor 2 d piping fastening device, and vibration-proof pad.
    Special note: in the air compressor exit strong vibration, cannot install the sensors, shall be installed after the gas storage.
    4, demand for air condition:
    A, the gas to be tested for single phase pipe flow, continuously flowing through a pipe.
    Before b, the gas flows through the flowmeter, the flow rate must be parallel to the pipe axis, can not have vortex flow.
    C, flow should be a subsonic, a pulse, its flow change slowly over time.
    5, the flowmeter installation requirements:
    Vortex street flowmeter to process the installation and use of the special requirements of environment is not too much, but any kind of flow measurement instrument has such a common, as far as possible to avoid vibration and high temperature environment as flow interference elements (such as compressor, separator, pressure regulating valve, reducer, and pipe, elbow, etc.), keep straight pipe before and after the instrument inside sleek straight, ensure to clean single-phase fluid measured medium, etc.

    Nine, note:
    1, special flange and straight pipe welding can't with the sensor.
    2, when installation should make the flow of sensor mark the direction of flow and the pipe.
    3, before the installation of sensor and the flange must be put away in sealing ring grooves.The location of the pressure and temperature measurement point, pressure downstream of the sensor in 3 ~ 5 dn, temperature measuring points in the downstream of 5 ~ 8 dn.
    4, when measuring high temperature medium, do not use heat insulation material to wrap around the sensor link rod.

    Five, connection of shielded cable, should as far as possible away from the interference of strong electromagnetic field.Absolutely not allowed with high voltage cable laying, shielded cable to shorten as far as possible, and shall not be volume, in order to reduce stray inductance, zui big length should be not more than 200 meters.
    6, before installation of sensors, pipeline cleaning must be conducted.Flow after rinse tube impurities, avoid clogging sensor.Measuring liquid pipe must be full of measured liquid, prevent the interference of bubbles.
    7, measuring gas pipelines to prevent the interference of reservoir fluid.Installation position as shown in figure 5.Replace the probe body under the high temperature and high pressure, it must be safe operation, high temperature protection.After cooling step-down replaceable probe at the bottom of the safety conditions.
    Ten, installation specification management:
    Flowmeter standard installation, to use the department in the subsequent management provide strong technical support, put forward the following specific requirements of the construction unit, after years of validation effect is very good.
    1, with 4 ~ 20 ma output, pulse output.
    2, GPRS remote transmission device with pulse input, input 4 ~ 20 ma.
    3, with power supply prevents thunder and lightning protection (4 ~ 20 ma) signal.
    4, instrument cabinets for: ark with UPS power supply, open and the socket, the GPRS communication devices, intelligent vortex flowmeter converter such as concentrated installation and lock.
    5, smooth instrument ark need concrete pier base, instrument protection grade for outdoor cabinet, the ark with insulating layer to prevent sun point-blank, ark with water proof function.
    6, domestic demand has left side table well enough straight pipe, facilitate intelligent vortex flowmeter test, compare and follow-up management.
    7, the design of intelligent vortex flow timing front must have at least 10 times of nominal menstruation (dn) 10 straight pipe, the back-end must leave more than 5 dn straight pipe, to ensure accurate measurement.
    8, shall be installed in accordance with the specifications and after the installation need measuring grounding, grounding resistance should be under 10 Ω.Equipotential connections using multiple strands of copper wires, cables should be greater than or equal to 16 was;Instrument grounding line using multiple strands of copper conductor, cable requirement was greater than or equal to 6.Grounding standard see GB50343-2009 "technical specification for building electronic information system lightning protection.
    Eleven, selection of points:
    Correct selection to ensure that the use of vortex flowmeter is better.Should choose what kind of vortex street flowmeter is based on the current body to determine the physical properties and chemical properties of the medium?Make the size of vortex flowmeter, flow range, lining materials, electrode materials and output current, etc?To be the nature of the flow volume and flow measurement requirements.
    1, precision function
    Precision grade and function in accordance with the requirements of measurement and choose the instrument using fine grade, cost-effective.Such as for trade settlement, product transfer and energy measurement occasions, should choose high precision grade, such as 1.0, 0.5, or higher level;Used in process control, according to the requirements of control choose not with precision grade;Some just check process flow, without having to do precise control and measurement, can choose lower precision grade, such as 1.5, 2.5, 4.0, and even then you can choose cheap plug-in vortex flowmeter.
    2, medium can be measured
    Medium velocity and diameter, full scale measurement generally medium, the full flow of vortex flowmeter can measure medium velocity in 0.5-12 m/s within the scope of selection, range is wide.Choose different instrument specifications (diameter) and process piping, the same shall consider whether measuring flow range within the scope of the flow velocity, namely when the pipeline flow rate is low, can not meet the requirement of the flow meter, or under the velocity measurement accuracy of the quasi cannot guarantee, the need to reduce the size instrument, which carry high tube flow velocity, measurement results are satisfied.
    3, the selection of vortex flow transmitter
    In saturated vapor measurement using VA type piezoelectric vortex flow transmitter, due to the vortex flow meter range wide, therefore, in practice, the measurement of saturated steam flow main consideration shall not be less than the lower limit of vortex flowmeters, that is to say, must satisfy the fluid flow rate shall be not less than 5 m/s.According to the size of the YongQiLiang chooses different caliber of vortex flow transmitter, rather than with the existing technology to choose transmitter diameter pipe size.
    The choice of 4 pressure transmitter, pressure compensation
    Because of the saturated steam pipe length, pressure fluctuation is bigger, pressure compensation must be used, considering the pressure, temperature and density, the relation between measurement using pressure compensation, because the pipeline saturated steam pressure in the range 0.3 0.7 MPa, pressure transmitter ranges 1 MPa.
    5, display instrument selection
    Display instrument intelligent flow display, a voltage compensation, the instantaneous flow and cumulative flow integrating function.

    Twelve, standard of flow range profile: unit (m3 / h)

    traffic 

    The liquid flow range

    Gas flow range

    Saturated steam flow range

    CAL

    Small flow

    Heavy traffic

    Small flow

    Heavy traffic

    Small flow

    Heavy traffic

    DN25

    0.9

    14

    8.3

    110

    13

    1500

    DN40

    2.5

    35

    26

    300

    25

    4400

    DN50

    3.3

    55

    36

    480

    40

    6800

    DN80

    8

    150

    90

    1300

    100

    19000

    DN100

    14

    240

    140

    2000

    160

    29000

    DN150

    38

    450

    290

    4100

    350

    66000

    DN200

    70

    850

    620

    7500

    620

    118000

    DN250

    130

    1300

    700

    12500

    970

    185000

    DN300

    180

    2000

    920

    16500

    1400

    267000

    13, selection of coding:

    Code name

    size

    Flow range ㎡/h(In the wei and control)

    ZW-LUGB-25

    DN25

    1 ~ 10(liquid)

    25 ~ 60(gas)

    Steam flow check specifications,DN300The above recommended plug-in vortex flowmeter

    ZW-LUGB-32

    DN32

    1.5 ~ 18(liquid)

    15-150(gas)

    ZW-LUGB-40

    DN40

    2.2 ~ 27(liquid)

    22.6 ~ 150(gas)

    ZW-LUGB-50

    DN50

    4 ~ 55(liquid)

    35 ~ 350(gas)

    ZW-LUGB-80

    DN80

    9 ~ 135(liquid)

    90 ~ 900(gas)

    ZW-LUGB-100

    DN100

    14 ~ 200(liquid)

    140 ~ 1400(gas)

    ZW-LUGB-150

    DN150

    32 ~ 480(liquid)

    300 ~ 3000(gas)

    ZW-LUGB-200

    DN200

    56-800(liquid)

    550 ~ 5500(gas)

    Code name

    function1

    N

    No temperature pressure compensation

    Y

    With temperature compensation

    Code name

    Output type

    F1

    4-20mAOutput (two-wire system)

    F2

    4-20mAOutput (three-wire system)

    F3

    RS485Communication interface

    Code name

    Measured medium

    J1

    liquid

    J2

    gas

    J3

    steam

    Code name

    The connection method

    L1

    Flange mounted

    L2

    Flange connection type

    Code name

    function2

    E1

    1.0level

    E2

    1.5level

    T1

    The normal temperature

    T2

    The high temperature

    T3

    steam

    P1

    1.6MPa

    P2

    2.5MPa

    P3

    4.0MPa

    W1

    internal3.6VThe power supply

    W2

    DC24VThe power supply

    N1

    Stainless steel

    N2

    Carbon steel

    N3

    Anti-corrosion type

    Fourteen,Order to choose selection guidelines:

    Name and model number of 1, 1), (2) the diameter, flow range, (3) whether or not to bring the attached so that we can correct selection for you, (4) using pressure, (5) the use of medium temperature.

    2, if has been selected by design units in the way of vortex street flowmeter types, please press type vortex flowmeter directly order from our sales department.

    3, when using occasions is very important, or the environment is complex, please try to provide the design drawings and detailed parameters, by wei experts in our audit checks for you.

    After-sales service commitment:

    1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

    2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

    3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

    4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.