<strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>
  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

    The pointer type rotor of steam flowmeter

    29分流鏇翼式蒸汽流量計(指鍼式).jpg
    • 29分流鏇翼式蒸汽流量計(指鍼式).jpg
    ZW-LFX series The pointer type rotor of steam flowmeter Is used for mass flowmeter metering flow thr…

    Description:

    Productoverview:

    ZW-LFX series The pointer type rotor of steam flowmeter Is used for mass flowmeter metering flow through the pipe in low saturated and superheated steam system, direct site cumulative steam metering, especially for small and medium enterprises, can provide a reliable basis for energy saving boiler. Flow meter for the mechanical instruments, used for steam measurement, the accuracy is not high. But the pressure can be adjusted conveniently, is mainly used for mechanical pointer type metering instrument in the industrial production process of saturated steam and superheat superheated steam flow is not too large, the flowmeter has the advantages of simple structure, stable and reliable, low pressure loss, the measured DC installed in the steam pipe steam metering cumulative quality (weight).

    Second, working principle:

    ZW-LFX series of <strong> pointer rotor steam flowmeter</strong> is used to measure the industrial production process of saturated steam and overheated steam flow meter. The main section of fluid, damper and indicator three parts, is a kind of differential pressure principle is shunt - meter.

    When the steam enters the body, because the throttling effect of orifice plate and nozzle, the inclined hole part of the steam enters the body through the shunt diversion pipeline, jet rotor impeller, a torque, the impeller shaft is arranged at the lower part of the damping damping blade, blade in the water filled radiator body rotation, the rotation by the damping effect of the impeller, kinetic energy this impeller can be effectively absorbed by the jet, the phase equilibrium in the impeller shaft braking torque torque and damping impeller speed of rotation. The steam enters the body is in proportion to shunt shunt in the pipeline, and the impeller speed and flow rate is proportional to size, so the impeller speed and through the full steam flow is proportional to the rotation of the impeller shaft, with the gear change to the appropriate speed, then the pointer through magnetic coupling to counter on the dial, can be directly read the numerical flow of steam. Equipped with pulse generator, we can realize the remote display. The specific figure:

                                                       

    Third, application:

    ZW-LFX series of <strong> pointer rotor type steam flow meter</strong> is a measure of the steam instrument can accurately measure the superheated steam and saturated steam flow accumulation. Through the counter dial can be directly read through all the weight steam table, also the output pulse signal, the two meter remote connection.Applicable to the petroleum, chemical industry, light industry, metallurgy, textile, food, medicine and other units of measurement using steam steam flow.

    Fourth, the main features:

    1, flow measurement range, accurate measurement of saturated steam and overheated steam (superheat is less than 20 DEG C) flow.

    2, in the pipeline installation of this flowmeter can easily change the flow range as long as the change of the nozzle or orifice.

    3, can be directly read out the accumulated flow, but also can realize the remote display.

    4, when the working pressure is changed, through the pressure adjusting device, can ensure accurate measurement.

    5, simple design, reliable structure, convenient maintenance.

    Five, technical parameters:

    1, medium: saturated steam and overheated steam (superheat is less than or equal to 30 DEG C);

    2, nominal diameter: DN25, DN50, DN80, DN100;

    3, Zui high working temperature: 240 degrees;

    4, the use of pressure range: 0.05 ~ 1.6MPa;

    5, compensation mode: manual pressure compensation;

    6, reading: reading;

    7, installation: horizontal installation. Must be installed in a horizontal straight tube, the indicator must be in the pipeline under the straight pipe section length to meet the requirements (10DN 5DN). The other according to the steam must be the direction of the arrow into the shell body.

    Six, installation and use:

    1, flow meter must be installed in a horizontal straight line section, pipe line length shall not be less than the nominal diameter of 10DN before and after section of straight pipe line length should not be less than the nominal diameter of 5DN. The inner diameter of the pipe must be the same size as the nominal flow meter. Do not put the meter installed in the pipeline Zui low, flowmeter indicator must be perpendicular to the line below.

    2, according to the steam flow to the meter shell protruding arrow direction, not the reverse. The user for convenient reading, need to change the direction of the dial, can unscrew the fastening indicator two M10 * 28 bolts, the indicator will rotate 90 degrees or 180 degrees, then bolt from the other two hole. But not the reverse toggle magnets, lest cause loosening of product failure.

    3, the machine before installation, must be on both sides of the pipeline cleaning net, so as to avoid clogging dirt into the flowmeter body.

    Before 4, two meter running, a water plug must open top chamber damping, the damping chamber filled with water after fastening, otherwise the rotor speed is too high will cause the damage and accumulation of errors.

    After 5, all the preparatory work is completed, the valve to be opened before and after work, after the opening of the valve opening to the need. Do not turn on too fast, so as to avoid the rotor damaged by the sudden shock.

    6, in the environment temperature is below zero to stop working, to prevent damp indoor water freezes, the water must be discharged from the outlet of the damping chamber. If the work in cold conditions to prevent freezing of water in damping, damping chamber outsourcing enough insulation layer, or filled with antifreeze in the damping chamber (water solution containing diethylene glycol 50%).

    7, the dial reading: this instrument according to different diameter, orifice plate is provided with 10kg, 100kg two dial.Figure 3A shows the 10kg dial, its long pointer per week is 10kg, the length of needle clockwise rotation, as a ratio to carry 10:1, go a week long pointer, a short walk *. * short a week away, second STS move...... , by analogy, to fifth short walk after a week, the pointer are back to zero.

    The DN25 instrument must use the calibration correction factor to correct values, both the readings on the calibration correction coefficient, the actual steam flow shows that the formula is: G=G '- lambda; G: (kg) G' actual flow table indicating the flow (kg): lambda: Specifies the correction coefficient. A value is obtained by calibration, marked on the nameplate factory.

    8, pressure adjustment: to ensure the measurement accuracy in steam pressure changes, a pressure compensation adjustment mechanism in the indicator, the pressure adjustment of the dial indicator should be consistent with the steam pressure through the shell, if not, should be adjusted to the same. Adjustment method; open the cover (2), (5) the back nut loosen scale rod (4) circular dial (3) on the pressure indicator scale line alignment scale (1) on the corresponding pressure value (consistent with working pressure) and then tighten the back nut.

    Seven, note the use and maintenance:

    The use of 1 meter, before operation, must be filled with clean water to damp indoor. First the two injection screw (avoid cavity gas row not clean, water filled, and then to fill the interior damping) clean water. Otherwise, the instrument will lead to damage or reduce the instrument precision and life;

    2 meter, stop running, must be damp indoor water from the outlet on the net, to prevent the winter ice water meter and prevent bad water corrosion of instrument;

    3, flow meter in environmental temperature below 0 DEG C when used in the damping chamber water by adding antifreeze (appropriate damping liquid concentration for ethylene glycol solution of 50%);

    4, the installation should be flowmeter before flushing clean, prevent dirt from entering the instrument with the instrument damage caused by steam. The steam flowmeter is put into operation, should gradually open the valve, do not suddenly open the valve, to avoid damage to parts;

    5, put into use, should be based on the steam working pressure, adjust the compensation, the compensation scale value of working pressure is consistent with the actual work, to ensure the accuracy of flowmeter.

    Eight, the rated flow table (unit: Kg/h )

    Steam pressure

    MPa

    DN25

    DN50

    DN80

    DN100

    Throttling element

    1#

    2#

    3#

    1#

    2#

    3#

    1#

    2#

    3#

    1#

    2#

    3#

    Zero Point Zero Five

    Seventy

    Thirty-five point three

    Eighteen

    Six hundred and sixty

    Two hundred and sixty-five

    One hundred and thirty-three

    One thousand three hundred and twenty-five

    Six hundred and sixty

    Two hundred and sixty-five

    Two thousand six hundred and fifty

    One thousand three hundred and twenty-five

    Six hundred and sixty

    Zero point one

    Eighty

    Forty

    Twenty

    Seven hundred and fifty

    Three hundred

    One hundred and fifty

    One thousand and five hundred

    Seven hundred and fifty

    Three hundred

    Three thousand

    One thousand and five hundred

    Seven hundred and fifty

    Zero point two

    Ninety-six point seven

    Forty-eight

    Twenty-four

    Nine hundred and fifteen

    Three hundred and sixty-six

    One hundred and eighty-eight

    One thousand eight hundred and thirty

    Nine hundred and fifteen

    Three hundred and sixty-six

    Three thousand six hundred and sixty

    One thousand eight hundred and thirty

    Nine hundred and fifteen

    Zero point three

    One hundred and ten

    Fifty-five

    Twenty-seven point five

    One thousand and fifty

    Four hundred and twenty

    Two hundred and ten

    Two thousand and one hundred

    One thousand and fifty

    Four hundred and twenty

    Four thousand and two hundred

    Two thousand and one hundred

    One thousand and fifty

    Zero point four

    One hundred and twenty-two

    Sixty-one

    Thirty point seven

    One thousand one hundred and sixty-five

    Four hundred and sixty-six

    Two hundred and thirty-three

    Two thousand three hundred and thirty

    One thousand one hundred and sixty-five

    Four hundred and sixty-six

    Four thousand six hundred and sixty

    Two thousand three hundred and thirty

    One thousand one hundred and sixty-five

    Zero point five

    One hundred and thirty-three

    Sixty-six point six

    Thirty-three point three

    One thousand two hundred and seventy

    Five hundred and eight

    Two hundred and fifty-four

    Two thousand five hundred and forty

    One thousand two hundred and seventy

    Five hundred and eight

    Five thousand and eighty

    Two thousand five hundred and forty

    One thousand two hundred and seventy

    Zero point six

    One hundred and forty-three

    Seventy-one

    Thirty-six

    One thousand three hundred and sixty-five

    Five hundred and forty-seven

    Two hundred and seventy-three

    Two thousand seven hundred and thirty

    One thousand three hundred and sixty-five

    Five hundred and forty-seven

    Five thousand four hundred and seventy

    Two thousand seven hundred and thirty

    One thousand three hundred and sixty-five

    Zero point seven

    One hundred and fifty-two point six

    Seventy-six

    Thirty-eight

    One thousand four hundred and fifty

    Five hundred and seventy-six

    Two hundred and ninety

    Two thousand and nine hundred

    One thousand four hundred and fifty

    Five hundred and seventy-six

    Five thousand seven hundred and sixty

    Two thousand and nine hundred

    One thousand four hundred and fifty

    Zero point eight

    One hundred and sixty-one point six

    Eighty point seven

    Forty point seven

    One thousand five hundred and forty

    Six hundred and fifteen

    Three hundred and fifteen

    Three thousand one hundred and fifty

    One thousand five hundred and forty

    Six hundred and fifteen

    Six thousand one hundred and fifty

    Three thousand one hundred and fifty

    One thousand five hundred and forty

    Zero point nine

    One hundred and seventy

    Eighty-five

    Forty-two point seven

    One thousand six hundred and twenty

    Six hundred and forty-eight

    Three hundred and twenty-four

    Three thousand two hundred and forty

    One thousand six hundred and twenty

    Six hundred and forty-eight

    Six thousand four hundred and eighty

    Three thousand two hundred and forty

    One thousand six hundred and twenty

    One

    One hundred and seventy-six point six

    Eighty-eight point seven

    Forty-four point seven

    One thousand six hundred and ninety-five

    Six hundred and seventy-seven

    Three hundred and thirty-nine

    Three thousand three hundred and ninety

    One thousand six hundred and ninety-five

    Six hundred and seventy-seven

    Six thousand seven hundred and seventy

    Three thousand three hundred and ninety

    One thousand six hundred and ninety-five

    One point one




    One thousand seven hundred and sixty

    Seven hundred and six

    Three hundred and fifty-three

    Three thousand five hundred and thirty

    One thousand seven hundred and sixty

    Seven hundred and six

    Seven thousand and sixty

    Three thousand five hundred and thirty

    One thousand seven hundred and sixty

    One point two




    One thousand eight hundred and thirty-five

    Seven hundred and thirty-three

    Three hundred and sixty-seven

    Three thousand six hundred and seventy

    One thousand eight hundred and thirty-five

    Seven hundred and thirty-three

    Seven thousand three hundred and thirty

    Three thousand six hundred and seventy

    One thousand eight hundred and thirty-five

    One point three




    One thousand and nine hundred

    Seven hundred and sixty

    Three hundred and eighty

    Three thousand and eight hundred

    One thousand and nine hundred

    Seven hundred and sixty

    Seven thousand and six hundred

    Three thousand and eight hundred

    One thousand and nine hundred

    One point four




    One thousand nine hundred and sixty-five

    Seven hundred and eighty-five

    Three hundred and ninety-three

    Three thousand nine hundred and thirty

    One thousand nine hundred and sixty-five

    Seven hundred and eighty-five

    Seven thousand eight hundred and fifty

    Three thousand nine hundred and thirty

    One thousand nine hundred and sixty-five

    One point five




    Two thousand and fifteen

    Eight hundred and ten

    Four hundred and three

    Four thousand and thirty

    Two thousand and fifteen

    Eight hundred and ten

    Eight thousand and one hundred

    Four thousand and thirty

    Two thousand and fifteen

    One point six




    Two thousand and ninety

    Eight hundred and thirty-five

    Four hundred and eighteen

    Four thousand one hundred and eighty

    Two thousand and ninety

    Eight hundred and thirty-five

    Eight thousand three hundred and fifty

    Four thousand one hundred and eighty

    Two thousand and ninety

    Display pointer

    0-10kg

    0-100kg

    0-10kg

    0-100kg

    0-10kg

    0-100kg

    Nine, nominal pressure and working temperature:

    The nominal diameter ( Mm)

    Precision grade

    Nominal pressure

    The use of temperature (c)

    The ambient temperature (c)

    Twenty-five

    Two

    One

    One hundred and eighty-three

    -20~+50

    Fifty

    Two point five

    One point six

    Two hundred and twenty

    Eighty

    Two point five

    One point six

    Two hundred and twenty

    One hundred

    Two point five

    One point six

    Two hundred and twenty

    Ten, dimensions and installation:
    One Size and shape

    Nominal diameter

    Installation method

    Flange connection

    flange

    LFX

    external diameterD

    Screw center distance D1

    Screw N-D

    L

    H

    B width

    weightKg

    Twenty-five

    Horizontal installation

    GB/T17241

    .6-.7-1998

    One hundred and fifteen

    Eighty-five

    The diameter of 14 4-

    Two hundred

    Four hundred and thirty-seven

    One hundred and fifty-three

    Twenty-seven

    Fifty

    One hundred and sixty

    One hundred and twenty-five

    The diameter of 18 4-

    Three hundred and twenty-four

    Six hundred and eighty

    One hundred and ninety-six

    Thirty-two

    Eighty

    One hundred and ninety-five

    One hundred and sixty

    8- is 18

    Three hundred and twenty-four

    Seven hundred and ten

    One hundred and ninety-six

    Forty

    One hundred

    Two hundred and fifteen

    One hundred and eighty

    The diameter of 18 8-

    Three hundred and twenty-four

    Seven hundred and thirty

    One hundred and ninety-six

    Forty-five

    Two Installation mode:
    This instrument has the advantages of convenient installation, the installation please pay attention to the following matters:
    One And the center line flowmeter must be installed in the steam pipeline horizontal straight line, the meter inlet pipe length not less than 10DN The export side, straight length not less than 5DN .
    Two And flowmeter before the operation, must be filled with water from the water inlet.
    Three And when the flowmeter at ambient temperature Zero The use should pay attention to antifreeze, antifreeze should be used in the radiator into the water (containing about 50% Aqueous solution of diethylene glycol) to replace.

    Eleven, the selection of encoding:



    Explain

    Type code

    ZW-LFX

    Steam flow meter rotor (Zhongwei control)

    -


    Match the types of connections between

    Nominal diameter

    Twenty-five

    Nominal diameter 25mm

    Fifty

    Nominal diameter 50mm

    Eighty

    Nominal diameter 80mm

    One hundred

    Nominal diameter 100mm

    /


    Match the types of connections between

    Throttle unit no.

    One

    One The number of throttling element

    Two

    Two The number of throttling element

    Three

    Three The number of throttling element

    Give an example: ZW-LFX-50/2 Explain: Rotor type steam flowmeter Nominal diameter. 50mm , Two The number of throttling element.

    Twelve, design selection and ordering information:

    1, the use of steam should be saturated steam or superheated steam (micro superheat temperature not exceeding 20 degrees);

    In 2, the nominal pressure range within the approximate range of flow meter or working flow;

    3, if the diameter selected does not match with the actual diameter, the transformation pipeline, but must meet the requirements of straight pipe;

    4, whether with remote instrumentation and models;

    5, if there is no selection and installation experience, I can assist the selection unit.

    Customer service service commitment:

    1, from the date of the contract, I Zhongwei company to provide products to provide free maintenance and maintenance services, life-long maintenance service commitment;

    2, Jiangsu Zhongwei instrument limited company sales manager will regularly communicate with customers, understand the use of the product, and solve customer problems in the use process, to provide free technical support;

    3, the warranty period the occurrence of man-made damage, the company responsible for the maintenance, and collect the resulting maintenance costs;

    4, product quality problems or are not satisfied with the product, the user can choose the unconditional return, my company does not charge any fees, quality problems, bear the freight back and forth.


    Browse:
    Return To The Top

    分(fen)亯到:

    eYtzRjavascript:void();

    <strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>