  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

    Small oval gear flowmeter

    11橢圓齒輪流量計(微小).jpg
    • 11橢圓齒輪流(liu)量計(微(wei)小).jpg
    ZW - LC seriesSmall oval gear flowmeterIs a pointer, according to the word wheel accumulated countin…

    Description:

    ZW - LC seriesSmall oval gear flowmeterIs a pointer, according to the word wheel accumulated counting device and back to zero device light volumetric flow meter, widely used in various industrial fields of liquid flow control, is suitable for various kinds of liquid measurement, such as crude oil, diesel oil, petrol, etc., has a large range, high precision, use and maintenance is convenient wait for a characteristic, choose different materials, can meet the petroleum, chemical, pharmaceutical, food, metallurgy, electric power, transportation and so on various areas of liquid flow metering.

    Second, the working principle:

    ZW - LC series small oval gear flowmeter measurement part is mainly composed of two mutually meshing elliptical gear and shell (measuring room), elliptical gear turn every week the parallelism of the measured medium quality for half moon volume 4 times, by the elliptical gear meteor millions of volume flow rate Q: Q = 4 n nu 0

    Type:

    N - the rotation of the elliptical gear frequency (r/s);

    Nu 0 - half moon part volume (Mr.).

    So, in the half moon volume of the oval gear flowmeter nu 0 given conditions, as long as the measure of elliptic gear rotational speed n, can know the measured medium flow.

    Elliptic flow meter flow signals (that is, the elliptic gear rotating speed n) showed that has two kinds of on-site display and remote transmission.

    In situ show that the gear rotation through a series of deceleration and adjust speed than institutions, directly connected to the instrument panel on the indicating needle, and the total amount after mechanical counter display.

    Far eastone shows mainly through the reduction gear after * magnet rotates, making spring relay contact with * magnet synchronization to make or break the rotation of the same frequency, thus far to another display instrument issued by electrical impulses.

    Applications:

    ZW - LC series small oval gear flowmeter is widely applied in the liquid flow in the field of industrial control, is suitable for various kinds of liquid measurement, such as crude oil, diesel oil, petrol, etc., has a large range, high precision, use and maintenance is convenient wait for a characteristic, choose different materials, can meet the petroleum, chemical, pharmaceutical, food, metallurgy, electric power, transportation and so on various areas of liquid flow metering.

    Four, the main features:

    1, high measuring accuracy;

    2, pipeline installation condition has no effect on measuring accuracy;

    3, can be used in high viscosity liquid measurement;

    4, wide range of degrees;

    5, direct reading instrument without external energy can directly obtain the cumulative, total amount, clear, easy to operate.

    Five, the technical parameters:

    1, the nominal diameter: DN10 ~ DN200;

    2, working temperature: - 10 ℃ ~ + 200 ℃;

    3, nominal pressure: 0.6 ~ 10 mpa;

    4, medium viscosity: 0.3 ~ 2000 mpa. S;

    5, precision grade: 0.2;0.5;

    6, quantity than: ";

    7, shell material: cast iron;Cast steel;Stainless steel;

    8, mode of power supply: 3.6 VDC built-in lithium battery (once in two years);Outside for 24 VDC (optional);

    9, output signal: 4 ~ 20 ma two wire;Pulse 0 ~ 1000 hz;RS232 / RS485 (or consultation according to the requirements of customers;QF or GF transmitter;

    10, protection level: IP65 IP67;

    11, explosion-proof level: Exia Ⅱ CT4 and Exd Ⅱ CT4;

    12, header display: pointer display (single cumulative flow);Liquid crystal display (total flow and transient flow);

    13, connection mode: flange.

    14, optional accessories: meter filter

    Flow meter filter is liquid pipeline and liquid flow meter of auxiliary equipment, it can be filter out all kinds of foreign bodies in the liquid, so as to prevent blockage and ensure the normal operation of the instrument.Ordinary filter shell USES cast iron, the mesh is made of stainless steel cloth.Stainless steel filter material are all made of acid steel.Diameter of 25 mm below the filter for y type, more than 40 mm for u.

    Six, error calculation and adjustment:

    1, the basic error of flowmeter, by the verification flow point of all measured values respectively press type calculation: (volume) E = Vm - 100% (V/V

    E - meter error (generally refers to the cumulative error) take two significant figures.

    The Vm - meter measured values (i.e., values)

    V - were revised, flowmeter standard device measured value (that is, the actual value) from the basic formula of error, when the Vm > V, flowmeter fundamental error for "+" values, said flowmeter is going faster.

    Vm < V, flowmeter basic error for "-", said flowmeter walked slowly.

    2, in order to make the error of flowmeter, within the basic error limit is often the need for error.By changing in counter namely inside a pair of adjusting gear (tooth) are adjusted to change the mechanical transmission ratio, so that the flow meter's worth to adjust.

    3, error adjustment can't change the flow characteristic of the flowmeter, the characteristic curve of artificially in a new coordinate system.

    4, in general, in the rules (or actual use) flow within the scope of its basic flow check point error range is not big five, the regulation accuracy of basic error limits, all can be adjusted by the error flowmeter qualified basic error.

    Flow meter has been used, usually with the adjustment of the original gear set first for error detection, and then according to the error of the specific situation to adjust error.

    Seven, installation method:

    1, before installation shall be thoroughly clean the pipe and filter in front of the meter installation, in order to prevent debris into the meter.When measured liquid containing gas, should install air separator.

    2, should pay attention to must take meter oval gear shaft United States level, namely the dial and perpendicular to the plane.Flow adjustment and start, shut off the valve should be installed in the import and export of flow meters respectively.

    3, flowmeter shell on the arrow pointing in the direction of piping shall be installed with the liquid flow in the same direction.

    4, the continuous flow of pipeline, the installation of flowmeter horizontal line should be equipped with a bypass valve, in order to regular cleaning and maintenance.On the vertical pipe flow meter, shall be installed in the bypass duct to prevent debris into the instrument.

    Eight, note:

    1, right after installation, in accordance with the requirements when using can ensure enough accuracy, usually the cumulative value of precision can reach 0.5, is a more accurate flow meters.

    2, however, if the use of the measured medium flow rate is too small, the instrument will highlight the influence of the leakage error, can't guarantee enough accuracy of measurement.

    3, therefore, different specifications have a permitted to use the traffic, only when the actual measured flow is greater than the lower limit value, the measurement precision can be guaranteed.

    4, secondly, when using, pay attention to the temperature of the measured medium cannot be too high, otherwise not only can increase the measurement error, and there are may be stuck in the gear.

    5, therefore, in the instrument by using temperature range.Use for a long time after the gear flow meter, the internal gear are corrosion and wear and tear, which affect measurement accuracy.

    6, therefore, often should observe, and regularly check removed, if conditions permit calibration on a regular basis as far as possible.

    Nine,The dimensions:

    table1, the size of the standard shape: unit: mm

    Nominal diameter

    L

    H

    A

    B

    D

    D1

    N (a)

    Φ

    10

    150

    100

    165

    210

    90

    60

    4

    14

    15

    170

    118

    172

    226

    95

    65

    4

    14

    20

    200

    150

    225

    238

    105

    75

    4

    14

    25

    260

    180

    232

    246

    115

    85

    4

    14

    40

    245

    180

    249

    271

    145

    110

    4

    18

    50

    340

    250

    230

    372

    160

    125

    4

    18

    65

    420

    325

    270

    386

    180

    145

    4

    18

    80

    420

    325

    315

    433

    195

    160

    8

    18

    100

    515

    418

    370

    458

    215

    180

    8

    18

    150

    540

    515

    347

    557

    280

    240

    8

    23

    200

    650

    650

    476

    720

    335

    295

    12

    23

    table2, cast steel, cast steel, high viscosity, high temperature cast steel standard dimension: unit: mm

    Nominal diameter

    L

    H

    B

    A

    D

    D1

    N (a)

    Φ

    15

    200

    138

    232

    180

    105

    75

    4

    14

    20

    250

    164

    220

    160

    125

    90

    4

    18

    25

    300

    202

    252

    185

    135

    100

    4

    18

    40

    300

    202

    293

    208

    165

    125

    4

    23

    50

    384

    262

    394

    312

    175

    135

    4

    23

    80

    450

    337

    452

    332

    210

    170

    8

    23

    100

    555

    442

    478

    310

    250

    200

    8

    25

    150

    540

    510

    557

    347

    300

    250

    8

    26

    200

    650

    650

    720

    476

    36

    310

    12

    26

    Cast iron, cast steel, high temperature type standard dimension: DN15 ~ DN25, A and B size according to the above-mentioned data add 160 mm hot extension tube: DN40 ~ DN80, A and B size according to the size of the table with 300 mm hot extension tube, the rest of the size with the table size accordingly.
    Table 3, stainless steel type standard dimension: unit: mm

    Nominal diameter

    L

    H

    B

    A

    D

    D1

    N (a)

    Φ

    15

    208

    120

    228

    172

    95

    65

    4

    14

    20

    236

    150

    238

    225

    105

    75

    4

    14

    25

    287

    195

    246

    232

    115

    85

    4

    14

    40

    265

    178

    349

    265

    145

    110

    4

    18

    50

    265

    178

    349

    265

    160

    125

    4

    18

    65

    365

    260

    436

    319

    180

    145

    4

    18

    80

    420

    305

    459

    324

    200

    160

    8

    18

    100

    515

    400

    554

    373

    220

    180

    8

    18

    150

    540

    515

    607

    397

    280

    240

    8

    23

    Ten, measuring range:
    Ordinary cast iron type (AType), cast steel,EType), stainless steel,B

    model

    ZW-LC-ACast iron

    ZW-LC-ECast steel

    ZW-LC-BStainless steel

    Nominal pressureMpa

    1.0 1.6

    2.5 4.0 6.4

    1.0 1.6

    Fluid viscosity to be tested

    2 ~200 Mpa.s

    Liquid temperature being measured

    - 20℃ ~+ 100

    flow The amount van wai m3/h

    model
    Precision grade

    ZW-LC-ACast iron

    ZW-LC-ECast steel

    ZW-LC-BStainless steel

    Nominal diameter
    mm

    0.5

    0.2

    0.5

    0.2

    0.5

    0.2

    10

    0.04~0.4

    0.1~0.4

    0.04~0.4

    0.1~0.4

    0.1~0.5

    0.1~0.5

    15

    0.25~1.5

    0.3~1.5

    0.25~1.5

    0.3~1.5

    0.3~1.5

    0.3~1.5

    20

    0.5~3

    0.6~3

    0.5~3

    0.6~3

    0.6~3

    0.6~3

    25

    1~6

    1.2~6

    1~6

    1.2~6

    1.2~6

    1.2~6

    40

    2.5~15

    3~15

    2.5~15

    3~15

    3~15

    3~15

    50

    4~24

    4.8~24

    4~24

    4.8~24

    4.8~24

    4.8~24

    65

    5~40

    8~40

    5~40

    8~40

    8~40

    8~40

    80

    10~60

    12~60

    10~60

    12~60

    12~60

    12~60

    100

    16~100

    20~100

    16~100

    20~100

    20~100

    20~100

    150

    32~190

    38~190

    32~190

    38~190

    38~190

    38~190

    200

    34~340

    68~340

    34~340

    68~340

    68~340

    68~340

    Eleven, selection of coding:

    The type code

    logo

    Material symbol

    Nominal diameter

    Nominal pressure

    counter

    transmitter

    precision

    Instructions (in the wei and control)

    ZW-LC-








    Oval gear flowmeter


    H







    Welded steel flow meter


    U







    Heat preservation jacket flowmeter


    N







    High viscosity liquid flow meter


    SP







    Food with a flow meter


    T







    High temperature type flowmeter


    Q







    Measuring gas flowmeter



    A






    Cast iron material



    E






    Cast steel material



    B






    Stainless steel material




    10





    For nominal diameter10mm




    15





    For nominal diameter15mm




    ……









    200





    For nominal diameter200mm





    1




    1.0MPa





    2




    1.6MPa





    3




    2.5MPa





    4




    4.0MPa





    6




    6.3MPa






    A ,A1



    Used forDN40The following,A1With the transmitter






    J1



    Used forDN50Above, can take transmitter






    A5 A6



    A5Single pointer word wheel display 
    A6
    Pointer cycle of zero







    GF-


    12VThree wire system photoelectric transmitter







    GF-


    24VThree wire system photoelectric transmitter







    MF


    4~20mATransmitter output







    DF


    Liquid crystal display with remote transmission4-20mA








    J1

    0.2Level of accuracy








    J2

    0.5Level of accuracy

    Twelve, design selection and order notes:

    1, choose oval gear flow timing, it is suggested that according to the measured liquid flow control meter flow range of 30 ~ 70% choose specifications;According to the fluid temperature, and the size of the pipeline pressure, and corrosion properties of liquid viscosity, etc to select flowmeter types;

    2, when ordering, please specify the model of flow meter, diameter (mm), whether to ask explosion-proof, name of the medium, flow range (m3 / h), work pressure (MPa), temperature (℃), medium viscosity (MPa) s), to measure the corrosion medium, the user must also specify the medium corrosion properties, medium concentration (%), medium temperature (℃);

    3, this product can according to user requirements, within the header assembly electrical/current transmission device;

    4, when ordering parts, please click and fill in the figure, the collapse of the list;

    5, user, if you have special request, please put forward in order;

    6, our company can provide filters, venting device with flow meter, intelligent flow integrating instrument.

    After-sales service commitment:

    1, our company sold by flow meter series products within twelve months appear quality problem, is responsible for free maintenance.

    2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

    3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

    4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

    5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.


    Browse: