<strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>
  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

    Glass tube rotameter

    18玻瓈(li)筦轉子流量計01.jpg
    18玻瓈筦轉子流量(liang)計03.jpg
    18玻瓈筦轉子流量計(ji)02.jpg
    • 18玻瓈筦轉子流量計01.jpg
    • 18玻瓈筦轉(zhuan)子流(liu)量計03.jpg
    • 18玻瓈筦轉子流量計02.jpg
    ZW-LZB/LZJ series Glass tube rotameter According to its purpose and scope can be divided into: ordin…

    Description:

    Productoverview:

    ZW-LZB/LZJ series Glass tube rotameter According to its purpose and scope can be divided into: ordinary type, ribbed vascular type, small flow and low profile type, corrosion type, laboratory type, insulation type, alarm type and high pressure type eight series. According to the formulation of national instrument series, regardless of which Zui series, ranging from 1 to 100 mm in diameter and a total of 12 numbers, can measure the flow range: liquid (water) 0.1 ml / min to 40 cubic meters / hour, gas (air) 1 ml / min to 1000 cubic meters / hour. For environmental protection equipment of the glass rotameter is generally not more than 10 mm diameter, the flow measurement of small flow range.

    Two, work principle:

    ZW-LZB/LZJ series of glass tube rotameter is mainly composed of a bottom enlarged glass tube and a cone with the magnitude of fluid flow moves up and down the stainless steel float. The fluid flows through the cone bottom tube, buoyancy A fluid kinetic energy generated on the float lift S and fluid to float up, when the lift and buoyancy of A and S is equal to the gravity float G, float in the balance, stable at a certain height position, cone scale on the tube indicates that the fluid flow value.

    ZW-LZB- (F) for smooth wall cone tube flowmeter tube diameter meter above DN15, the float remained stable through the movement, the guide rod; ZW-LZJ- (F) three meter cone tube guide rib, the float remained stable. Through the meter diameter of DN10 or less connected by a hose, equipped with needle flow control valve; path DN15 flowmeter with flange connection.

    Three, application:

    ZW-LZB/LZJ series of glass tube rotameter is mainly used in chemical, petroleum, light industry, medicine, chemical fertilizer, chemical, food, dyestuff, environmental protection and scientific research departments, used to measure single-phase non pulsating (liquid or gas) fluid flow.

    Anticorrosion type is mainly used for the detection of corrosive liquid and gas medium flow, such as acid and alkali, oxidant, strong oxidizing acid, organic solvents and other corrosive gas or liquid medium flow detection.

    Four, main features:

    1, small pressure loss. In the process of using, can be fully utilized, without a lot of effort too much, all the pressure can be fully used, there will be no loss.

    2, reliable performance. Glass rotor flowmeter in operation, frequent failure will not ensure good operation. When people are in the process of using, don't worry about running for it. Good performance, high reliability, can be assured use.

    3, simple structure, convenient installation and use. The structure of the glass rotameter is simple, the installation is very convenient, can be installed in a short period of time.

    Fifth, technical parameters:

    1, size: DN2 ~ 100mm;

    2, measuring range: water (20 C): 1L/h ~ 100m3/h, gas (101325Pa, 20 C): 16L/h ~ 3000m3/h;

    3, the range ratio: 10: 1;

    4, precision grade: grade 1.5, grade 2.5, grade 4;

    5, nominal pressure: DN4 ~ 10 1.0MPa, 50 0.6MPa, DN15 ~ DN80 ~ 100 0.4MPa;

    6, working temperature: less than or equal to 120 DEG c;

    7, connection: hose, metal pipe, flange (GB/T9119-2000);

    8, material: flange, float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type LZB-B.

    Note: the wetted materials for use in 316, is a model for the LZB-Bo, can be customized.

    For stainless steel PTFE is type LZB-BF (or BoF), can be customized.

    Six, selection method:

    1, measurement. Measuring the media type, size, pressure and chemical properties. Such as liquid and gas medium, the corrosive medium should choose corrosion resistance meter.

    2, the performance of flowmeter. The above conditions are identified in general, if the price is no big change, may be preferred needle valve is arranged on the upper part of the large circulation flow meter; hole, direct flow scale; simple structure; small exterior dimensions etc.. Such as small flow range, you can choose to use the ball float type, because of its measurement stability, not easy dust, high precision, good interchangeability.

    The price of 3, according to the. Generally speaking, the high price of high precision. According to the measurement instruments such as precision grade, only through the medium of control measure, the operation adjustment, after always stabilize the throughput, so the accuracy is minor.

    Seven, matters needing attention:

    1, don't put the front cover removed, because the glass tube easy blasting, shell to protect.

    2, when used in winter, should pay attention to keep warm, if the night is not used, the residual liquid in the flow discharged, so as not to freeze broken glass tube.

    3, to the pipeline installation, first look at the downstream pipeline is in a straight line. If not in a straight line, will not only affect the measuring accuracy of the instrument, but also will damage the flowmeter.

    4, when the valve is opened, will slowly open, if the estimated flow to floating rotor, and the rotor does not move up, immediately stop valve, tap the pipeline, so that the rotor can slowly rise.

    5, first observed within the flow tube is intact, glass tube is easy to damage; second is to remove the rotor fixture, gently slide backward to see whether the rotor freely up and down. If not free to slide, vibration plate gently. If we can not slide, would need professional solutions.

    Eight, specifications and measuring range:

    1, ordinary type:

    LZB-2

    LZB-3

    Model

    LZB-4

    LZB-6

    LZB-10

    Phi 2

    Phi 3

    Nominal diameter mm

    Phi 4

    Phi 6

    Phi 10

    Less than or equal to 1

    Less than or equal to 1

    The working pressure of MPa

    Less than or equal to 1

    Less than or equal to 1

    Less than or equal to 1

    + 4

    + 4

    Basic error limit%

    + 4

    + 2.5

    + 2.5

    1:10

    1:10

    The scope of

    1:10

    1:10

    1:10

    0.4~4

    2.5~25

    liquid
    Ml/min

    measuring range

    liquid
    L/h

    1~10

    2.5~25

    6~60

    0.6~6

    4~40

    1.6~16

    4~40

    10~100

    1~10

    6~60

    2.5~25

    6~60

    16~160

    1.6~16

    10~100

    6~60

    40~400

    Gas
    Ml/min

    Gas
    L/h

    16~160

    40~400

    100~1000

    10~100

    60~600

    16~160

    100~1000

    25~250

    60~600

    160~1600

    25~250

    160~1600

    40~400

    100~1000

    250~2500

    2, ordinary type:

    Model

    LZB-15

    LZB-25

    LZB-40

    LZB-50

    LZB-80

    LZB-100

    Nominal diameter

    Phi 15

    Phi 25

    Phi 40

    Phi 50

    Phi 80

    Phi 100

    Ratio measurement

    1:10

    1:10

    1:10

    1:10

    1:5 1:10

    1:5

    Working pressure

    Less than or equal to 0.6

    Less than or equal to 0.6

    Less than or equal to 0.6

    Less than or equal to 0.6

    Less than 0.4

    Less than 0.4

    Precision grade

    Two point five

    One point five

    One point five

    One point five

    One point five

    One point five

    Flow range

    liquid

    (m3/h)

    16-160 (L/h)

    40-400 (L/h)

    0.16-1.6

    0.4-4.0

    1-10

    5-25

    25-250 (L/h)

    60-600 (L/h)

    0.25-2.5

    0.6-6.0

    1.6-16

    8-40

    40-400 (L/h)

    100-1000 (L/h)





    Gas

    (NM3/h)

    0.25-2.5

    1-10

    4-40

    10-100

    50-250

    120-600

    0.4-4.0

    1.6-16

    6-66

    16-160

    80-400

    200-1000

    0.6-6.0

    2.5-25





    3, corrosion resistance:

    Model

    LZB-15F

    LZB-25F

    LZB-40F

    LZB-50F

    LZB-80F

    LZB-100F

    Nominal diameter

    Phi 15

    Phi 25

    Phi 40

    Phi 50

    Phi 80

    Phi 100

    Ratio measurement

    1:10

    1:10

    1:10

    1:10

    1:5 1:10

    1:5

    Working pressure

    Less than or equal to 0.6

    Less than or equal to 0.6

    Less than or equal to 0.6

    Less than or equal to 0.4

    Less than or equal to 0.4

    Less than or equal to 0.4

    Precision grade

    Four

    Two point five

    Two point five

    Two point five

    Two point five

    Two point five

    Flow range

    liquid

    (m3/h)

    16-160 (L/h)

    40-400 (L/h)

    0.16-1.6

    0.4-4.0

    1-10

    5-25

    25-250 (L/h)

    60-600 (L/h)

    0.25-2.5

    0.6-6.0

    1.6-16

    8-40

    40-400 (L/h)

    100-1000 (L/h)





    Gas

    (NM3/h)

    0.25-2.5

    1-10

    4.0-40

    10-100

    50-250

    120-600

    0.4-4.0

    1.6-16

    6.0-66

    16-160

    80-400

    200-1000

    0.6-6.0

    2.5-25





    4, LZB-S:

    Model

    LZB-15S

    LZB-25S

    LZB-50S

    LZB-80S

    Nominal diameter mm

    Phi 15

    Phi 25

    Phi 50

    Phi 80

    The working pressure of MPa

    Less than or equal to 0.6

    Less than or equal to 0.6

    Less than or equal to 0.6

    Less than 0.4

    The basic error indication limit%

    + 2.5

    + 2.5

    + 2.5

    + 2.5

    measuring range

    Liquid L/h

    4~90

    70~700

    450~7000

    7000~30000

    Stainless steel
    Flanges, a float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type ZW-LZB- (B).
    Wetted materials such as the need to use 316, then type ZW-LZB- (Bo), can be customized.
    For stainless steel PTFE is type ZW-LZB- (BF) (or BoF), can be customized.
    PTFE type
    Base, float, needle with polytetrafluoroethylene (PTTFE). Support plate and screws made of stainless steel.

    Nine, appearance and installation dimensions:

    Table 1,

    Path

    The size (mm)

    A

    B

    C

    D

    E

    Two

    One hundred and ten

    One hundred and thirty-two

    One hundred and fifty

    M8 * 1

    31 x 26 (front)

    Three

    One hundred and ten

    One hundred and thirty-two

    One hundred and fifty

    M8 * 1

    31 x 26 (front)

    Four

    One hundred and seventy

    Two hundred and eight

    Two hundred and thirty-eight

    Phi 11

    40 x 34 (front)

    Six

    One hundred and seventy

    Two hundred and eight

    Two hundred and thirty-eight

    Phi 11

    40 x 34 (front)

    Ten

    One hundred and seventy

    Two hundred and eight

    Two hundred and thirty-eight

    Phi 11

    40 x 34 (front)

    Table two:

    Diameter (mm)

    The size (mm)

    A

    B

    C

    D

    E

    Fifteen

    Phi 95

    Phi 65

    Four hundred and seventy

    Phi 15

    With the diameter of 14 4-

    Twenty-five

    Phi 105

    Phi 78

    Four hundred and seventy

    Phi 25

    With the diameter of 14 4-

    Forty

    Phi 145

    Phi 110

    Five hundred and seventy

    Phi 40

    With the diameter of 18 4-

    Fifty

    Phi 160

    Phi 125

    Five hundred and seventy

    Phi 50

    With the diameter of 18 4-

    Eighty

    Phi 185

    Phi 150

    Six hundred and sixty

    Phi 80

    With the diameter of 18 4-

    One hundred

    Phi 205

    Phi 170

    Six hundred and sixty

    Phi 100

    With the diameter of 18 4-

    10, encoding selection:

    ZW-LZB

    -

    caliber

    function

    Description (Zhongwei control)



    DN2-100


    caliber


    No label

    Ordinary type

    F

    Corrosion proof type, PTFE base (for DN2~DN10) or carbon steel flange lining PTFE

    B

    All stainless steel material: 304 stainless steel

    B0

    All stainless steel material: 316 stainless steel

    F/B (B0)

    Type: stainless steel corrosion-resistant stainless steel flange (304 or 316) lined with PTFE (for DN15~DN100)

    ZW-LZB

    -

    .

    .

    Glass tube flowmeter

    Common type: mainly applicable to non corrosive medium measurement;

    Corrosion proof type: mainly suitable for corrosive medium measurement;

    All stainless steel type: mainly applicable to sanitary and weak corrosive medium measurement, can anti corrosive gas environment for use in;

    Stainless steel corrosion proof type: mainly suitable for corrosive media measurement, can anti corrosive gas environment in use.

    Eleven, ordering:

    1, according to the measurement of the fluid is a gas or liquid, the correct selection of ZW-LZB rotor flowmeter.

    2, the measured fluid is non corrosive with ordinary type, corrosive resistant type selection.

    3, please specify when ordering the names, the measured flow rate, pipe diameter and pressure, temperature, density, viscosity, etc.. According to the user's density of correction, making special flow gauge.

    4, according to the measurement range and measured fluid applications such as choosing the suitable type of the specifications. As the special requirements of the flowmeter, or call the sales department, and company.

    Customer service service commitment:

    1, our series of flowmeter series product quality problems within 12 months, responsible for free maintenance.

    2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

    3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

    4, the warranty period after the product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

    5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


    Browse:
    Return To The Top

    分亯到:

    LjEwAjavascript:void();

    <strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>