<strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>
  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
    0517-86918678
    Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
    Tel:0517-86918678
    Fax:0517-86918679
    Email:zhongweick@https://msxpack.com
    Post Encoding:211600

    Digital display type double metal thermometer

    5數字顯示雙金屬溫度計(ji)01.png
    • 5數字顯(xian)示雙金屬溫度計01.png
    WST series Digital display type double metal thermometer Axial, radial type, universal type header t…

    Description:

    Productoverview:
    WST series Digital display type double metal thermometer Axial, radial type, universal type header type selection. The thermometer probe rod length can be customized according to customer needs. The scene temperature display, intuitive and convenient safe and reliable, long service life; core pulling type thermometer can not stop short time maintenance or replacement of movement. The axial and radial type, 135 type, degree universal type, complete varieties, suitable for various on-site installation need.
    Two, work principle:
    WST series Digital display type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. The main components for industrial use is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
    Three, application:
    WST series Digital display type double metal thermometer It can directly measure the production process in a variety of -80 to +500 DEG C range of liquid, steam and gas temperature. Widely used in petroleum, chemical, machinery, shipbuilding, power, textile, printing and dyeing industry and scientific research departments.
    Four, main features:
    1, the scene display temperature, convenient, safe and reliable, long life and other characteristics.
    2, victims of mercury free, easy reading, strong shock.
    3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
    4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
    5, axial, radial type, 135ordm; type, universal type, complete varieties, suitable for various on-site installation need.

    Five, technical parameters:
    1, the implementation of standards: JB/T8803-1998 GB3836-83;
    2, dial diameter: 60100150;
    3, accuracy: (1, 1.5);
    4, thermal response time: less than 40S;
    5, protection grade: IP65;
    6, adjust the angle error: adjustment angle error should not exceed the range of 1%;
    7, back to the poor: the return difference should not be greater than the absolute value of the basic error limit;
    8, repeatability: repeatability limit should be less than the absolute value of basic error of 1/2.

    Six, matters needing attention
    1, can not be directly screw head;
    2, the length of choice to choose the standard size close to the (integer multiples of 50mm);
    3, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, the general recommended immersion length is greater than 100mm, 0-50 DEG C immersion length range is more than 150mm, to ensure the accuracy of measurement.
    4, should not be used to measure open container medium temperature.
    In 5, storage, installation and transportation, should avoid collision protection tube, do not allow the protection tube bending change, but not the table when using the wrench.
    6 regular inspection, under normal conditions of use should be. In general, every six months.
    7, not allowed to work in the strong vibration environment, to prevent the influence of double metal life, does not allow the use of electric contact in the control loop vibration occasions, so as not to affect the reliability.

    Seven, temperature range:

    The measuring range of C

    Applicable scope

    Industrial and commercial

    Laboratory and small

    -80 ~ +40

    B.

    B.

    -40 ~ +80

    B.

    B.

    0 ~ 50

    B.

    B.

    0 ~ 100

    B.

    B.

    0 ~ 150

    B.

    B.

    0 ~ 200

    B.

    B.

    0 ~ 300

    B.

    B.

    0~400

    B.

    B.

    0 ~ 500

    B.

    B.

    Remarks:
    One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
    Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than FortySecond, diameter Phi 10 When the time constant is less than Thirty Seconds.
    Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .

    Eight, shape and size:

    structural style

    A

    B

    C

    E

    L

    D

    Axial type

    Sixty-five

    Twenty-three

    Seventy-three

    -

    Seventy-five
    One hundred
    One hundred and fifty
    Two hundred
    Three hundred
    Four hundred
    Five hundred
    Seven hundred and fifty
    One thousand

    Phi 6
    Phi 8
    Phi 10

    One hundred and five

    Twenty-three

    Seventy-three

    -

    One hundred and fifty-five

    Twenty-three

    Seventy-three

    -

    Radial type

    Sixty-five

    Fifty

    One hundred and ten

    Thirty-four

    One hundred and five

    Fifty

    One hundred and ten

    Thirty-four

    One hundred and five

    Fifty

    One hundred and ten

    Thirty-four

    135 degrees to type

    One hundred and five

    Twenty-three

    Eighty-five

    -

    One hundred and fifty-five

    Twenty-three

    Eighty-five

    -

    Universal type

    One hundred and five

    Twenty-three

    One hundred and seventy-eight

    One hundred and twenty

    One hundred and fifty-five

    Twenty-three

    One hundred and seventy-eight

    One hundred and twenty

    Nine, the specific model name that said:

    One Digital display, axial type

    Model

    Measuring range

    Precision grade

    Protection tube material

    Specifications

    Fixed form

    D

    L

    WST-300

    -80 ~ +40
    -40 ~ +80
    0 ~ 50
    0 ~ 100
    0 ~ 150
    0 ~ 200
    0 ~ 300

    One point five

    1Cr18Ni9Ti
    Three hundred and four
    Three hundred and sixteen
    316L
    Hastelloy C-276

    Phi 60

    Seventy-five
    One hundred
    One hundred and fifty
    Two hundred
    Three hundred
    Four hundred
    Five hundred
    Seven hundred and fifty
    One thousand

    No fixed device

    WST-400

    Phi 100

    WST-500

    Phi 150

    WST-301

    Phi 60

    Movable external thread

    WST-401

    Phi 100

    WST-501

    Phi 150

    WST-302

    Phi 60

    The movable internal thread

    WST-402

    Phi 100

    WST-502

    Phi 150

    WST-303

    Phi 60

    Fixed thread

    WST-403

    Phi 100

    WST-503

    Phi 150

    WST-304

    Phi 60

    Fixed flange

    WST-404

    Phi 100

    WST-504

    Phi 150

    WST-305

    Phi 60

    Card set screw

    WST-405

    Phi 100

    WST-505

    Phi 150

    WST-306

    Phi 60

    WST-406

    Phi 100

    Sleeve flange

    WST-506

    Phi 150

    Two Radial type, digital display

    Model

    Measuring range

    Precision grade

    Protection tube material

    Specifications

    Fixed form

    D

    L

    WST-310

    -80 ~ +40
    -40 ~ +80
    0~50
    0~100
    From 0 to 150
    0~200
    0~300
    0~400
    0 ~ 500

    One point five

    1Cr18Ni9Ti
    Three hundred and four
    Three hundred and sixteen
    316L
    Hastelloy C-276

    Phi 60

    Seventy-five
    One hundred
    One hundred and fifty
    Two hundred
    Three hundred
    Four hundred
    Five hundred
    Seven hundred and fifty
    One thousand

    No fixed device

    WST-410

    Phi 100

    WST-510

    Phi 150

    WST-311

    Phi 60

    Movable external thread

    WST-411

    Phi 100

    WST-511

    Phi 150

    WST-312

    Phi 60

    The movable internal thread

    WST-412

    Phi 100

    WST-512

    Phi 150

    WST-313

    Phi 60

    Fixed thread

    WST-413

    Phi 100

    WST-513

    Phi 150

    WST-314

    Phi 60

    Fixed flange

    WST-414

    Phi 100

    WST-514

    Phi 150

    WST-315

    Phi 60

    Card set screw

    WST-415

    Phi 100

    WST-515

    Phi 150

    WST-316

    Phi 60

    WST-416

    Phi 100

    Sleeve flange

    WST-516

    Phi 150

    Three Digital display 135 degrees To type

    Model

    Measuring range

    Precision grade

    Protection tube material

    Specifications

    Fixed form

    D

    L

    WST-420

    -80 ~ +40
    -40 ~ +80
    0~50
    0~100
    0~150
    0~200
    0~300
    0~400
    0~500

    One point five

    1Cr18Ni9Ti
    Three hundred and four
    Three hundred and sixteen
    316L
    Hastelloy C-276

    Phi 100

    Seventy-five
    One hundred
    One hundred and fifty
    Two hundred
    Three hundred
    Four hundred
    Five hundred
    Seven hundred and fifty
    One thousand

    No fixed device

    WST-520

    Phi 150

    WST-421

    Phi 100

    Movable external thread

    WST-521

    Phi 150

    WST-422

    Phi 100

    The movable internal thread

    WST-522

    Phi 150

    WST-423

    Phi 100

    Fixed thread

    WST-523

    Phi 150

    WST-424

    Phi 100

    Fixed flange

    WST-524

    Phi 150

    WST-425

    Phi 100

    Card set screw

    WST-525

    Phi 150

    WST-426

    Phi 100

    Sleeve flange

    WST-526

    Phi 150

    Four Universal type, digital display

    Model

    Measuring range

    Precision grade

    Protection tube material

    Specifications

    Fixed form

    D

    L

    WST-480

    -80 ~ +40
    -40 ~ +80
    0 ~ 50
    0 ~ 100
    0 ~ 150
    0 ~ 200
    0 ~ 300
    0~400
    0~500

    One point five

    1Cr18Ni9Ti
    Three hundred and four
    Three hundred and sixteen
    316L
    Hastelloy C-276

    Phi 100

    Seventy-five
    One hundred
    One hundred and fifty
    Two hundred
    Three hundred
    Four hundred
    Five hundred
    Seven hundred and fifty
    One thousand

    No fixed device

    WST-580

    Phi 150

    WST-481

    Phi 100

    Movable external thread

    WST-581

    Phi 150

    WST-482

    Phi 100

    The movable internal thread

    WST-582

    Phi 150

    WST-483

    Phi 100

    Fixed thread

    WST-583

    Phi 150

    WST-484

    Phi 100

    Fixed flange

    WST-584

    Phi 150

    WST-485

    Phi 100

    Card set screw

    WST-585

    Phi 150

    WST-486

    Phi 100

    Sleeve flange

    WST-586

    Phi 150

    10, encoding selection:

    Serial number

    WST

    Digital display type double metal thermometer

    (Zhongwei control)

    Dial diameter

    -3


    Phi 60

    -4


    Phi 100

    -5


    Phi 150

    Dial form

    Zero


    The axial (straight)

    One


    Radial (angle)

    Two


    135 degrees to (an obtuse type)

    Eight


    Universal (angle adjustable type)

    Fixed form

    Zero


    No fixed device

    One


    Movable external thread

    Two


    The movable internal thread

    Three


    Fixed thread

    Four


    Fixed flange

    Five


    Card set screw

    Six


    Sleeve flange

    Type of protection

    -


    Ordinary type

    W


    Type of protection

    F


    Anti-corrosion type


    Browse:
    Return To The Top

    分(fen)亯(xiang)到:

    EjnGrjavascript:void();

    <strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>