  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
    0517-86918678
    Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
    Tel:0517-86918678
    Fax:0517-86918679
    Email:zhongweick@https://msxpack.com
    Post Encoding:211600

    Electric contact remote double metal thermometer

    5電接點遠傳雙(shuang)金屬溫度計.jpg
    • 5電接點遠傳雙金屬溫度計.jpg
    WSSX series Electric contact remote double metal thermometer Is wound into a double sheet metal ring…

    Description:

    Productoverview:
    WSSX series Electric contact remote double metal thermometer Is wound into a double sheet metal ring bent on. At the end of heating expansion, drives the pointer to rotate, the instrument will display the temperature value, and prevent environmental vibration in double metal thermometer internal filling silicone oil or double metal thermometer display separation part and a measuring part to achieve the seismic effect. Electric contact bimetallic thermometer and integrated seismic electric contact bimetallic thermometer and separate seismic electric contact bimetallic thermometer 2.
    Two, work principle:
    WSSX series Electric contact remote double metal thermometer Electrical contact device with mechanical electric contact.When the medium temperature changes, on the free end of the thin shaft and steering transmission mechanism to drive the movable contact and pointer rotation, indicating in the dial on the change of temperature value, and when the fixed contacts (upper and lower fixed contacts) instantaneous contact or disconnection of the relay and contactor circuit in the system, in order to achieve the purpose of automatic control and alarm.
    Three, application:
    WSSX series Electric contact remote double metal thermometer Is a measuring instrument used in temperature field production is not very high occasions, can be directly measured gas, steam temperature, temperature measurement at 80 degrees -500 degrees below zero within the scope of the paragraph from the design has the characteristics of waterproof, corrosion resistance, shock resistance, intuitive readings, sturdy and durable, widely used in petroleum the chemical, ships, machinery, power, textile, printing and other industrial occasions.
    Four, main features:
    1, the scene display temperature, convenient safe and reliable, long service life;
    2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
    3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
    4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
    5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
    Five, technical parameters:
    1, measurement range: -80~40 degrees, -40~80 degrees, 0~50, 100, 150, 200, 250 degrees, or specified by the user;
    2, precision class: 1.5;
    3, working pressure: Zui pressure 4.0Mpa;
    4, F4 coating thickness: ~0.8mm, can also be specified by the user;
    5, quality inspection by EDM micro flaw detection, voltage 12KV, frequency of 1.6 * 106Hz breakdown;
    6, material: ICr18Ni9Ti; metal protection tube or specified by the user;
    7, metal protection tube: phi 6, Phi 8, Phi 10, Phi 12;
    8, connecting dimensions: (1) movable external thread: M27 * 2, G3/4, G1/2, or specified by the user;
    (2): DN15, 20, flange 25, HG20593, or specified by the user;
    9, dial od: D= Phi 80, Phi 100, Phi 150.

    Note:
    1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
    2, installation, non twist instrument shell.
    3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
    4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
    5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
    6, do not use media exposure in measuring container.
    7, the use of the process should pay attention to check in time, probably in about 6 months.


    Seven, electrical parameters:

    Rated power (VA)

    Working voltage (V)

    Allow the current (A)

    Ten

    220VAC

    0.7A

    24VDC

    Eight, insulation resistance:

    Rated voltage

    DC voltage test (DC)

    insulation resistance

    24VDC

    One hundred

    Seven

    220VAC

    Five hundred

    Twenty

    Normal working conditions: air temperature -25-+55 Temperature relative humidity Less than 85 %.
    Set point error: set point error should not exceed the basic error limit One . Five Times.
    Switching difference: switching error should not exceed the basic error limit One . Five Times.
    Nine, technical data sheet:

    Model

    The measuring range of C

    Precision grade

    Protection tube material

    The specification of L (mm).

    Mounting and fixing device

    WSSX-400

    -40-+80

    0-+50

    0-+100

    0-+150

    0-+200

    0-+300

    0-+400

    0-+500

    One point five

    1Cr18Ni9Ti

    Three hundred and four

    Three hundred and sixteen

    316L

    Hastelloy C-276

    Seventy-five

    One hundred

    One hundred and fifty

    Two hundred

    Three hundred

    Four hundred

    Five hundred

    Seven hundred and fifty

    One thousand

    No fixed device

    WSSX-410

    WSSX-480

    WSSX-401

    Movable external thread

    WSSX-411

    WSSX-481

    WSSX-402

    The movable internal thread

    WSSX-412

    WSSX-482

    WSSX-403

    Fixed thread

    WSSX-413

    WSSX-483

    WSSX-404

    Fixed flange

    WSSX-414

    WSSX-484

    WSSX-405

    Card set screw

    WSSX-415

    WSSX-485

    WSSX-406

    Sleeve flange

    WSSX-416

    WSSX-486

    Ten, the selection of encoding:

    Serial number

    category

    Specifications

    Explain

    WSS

    X

    Electric contact type

    Double metal thermometer (Zhongwei control)

    Dial diameter

    -3


    Phi 60

    -4


    Phi 100

    -5


    Phi 150

    Dial form

    Zero


    The axial (straight)

    One


    Radial (angle)

    Two


    135 degrees to (an obtuse type)

    Eight


    Universal (angle adjustable type)

    Fixed form

    Zero


    No fixed device

    One


    Movable external thread

    Two


    The movable internal thread

    Three


    Fixed thread

    Four


    Fixed flange

    Five


    Card set screw

    Six


    Sleeve flange

    Type of protection

    -


    Ordinary type

    W


    Type of protection

    F


    Anti-corrosion type

    Example: universal type, dial diameter Phi 100 The temperature range. Zero ~ Four hundred C, One point five Activity level, external thread M27 * 2 Length. 450mm . WSSX-481 , Zero ~ Four hundred C, L=450 , M27 * 2 , One point fiveClass.

    Eleven, Design selection and ordering information :
    1, model;
    2, precision grade;
    3, temperature range;
    4, fixed form;
    5, the installation form of casing heat;
    6, the inserted length.
    Customer service service commitment:
    1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
    2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
    3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
    4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
    5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


    Browse:
    Return To The Top

    分亯到:

    uviRyjavascript:void();

    <strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>