  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
    0517-86918678
    Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
    Tel:0517-86918678
    Fax:0517-86918679
    Email:zhongweick@https://msxpack.com
    Post Encoding:211600

    Armored thermocouple

    16鎧裝熱電偶.jpg
    • 16鎧裝熱電偶.jpg
    WRNK series Armored thermocouple Has many advantages of high pressure resistance, bending, thermal r…

    Description:

    Productoverview:

    WRNK series Armored thermocouple Has many advantages of high pressure resistance, bending, thermal response time fast and durable, it and industrial assembly type thermocouple, as a measurement of the temperature transmitter, and usually display instrument and record instrument and electronic regulator supporting the use, at the same time as the temperature sensing element assembly type thermocouple. It can directly measure a kind of production process from the 0~1300 temperature range of liquid, steam and gas solids and surface temperature.

    Two, structure principle:

    WRNK series of <strong> armored thermocouple</strong> works, two different components of the conductor ends by welding, forming a loop direct temperature measuring end called the working end, the terminal end is called the cold end, also called the reference terminal. When the temperature difference between the working end and the reference end, will produce thermal current in the circuit, connected to display instrument, the instrument will indicate the corresponding temperature of the thermocouple electromotive force generated by the value of the.

    The thermocouple electromotive force will increase with the increase of temperature measuring end, only the size of Thermal EMF and thermocouple conductor material and the temperature difference between the two ends, and the length and diameter of independent power pole.

    WRNK series of <strong> armored thermocouple</strong> structure, is composed of a conductor, high insulation, magnesium oxide coat 1Cr18Ni9Ti stainless steel protective tube, one drawn by many. The product is mainly composed of armored thermocouple junction box, terminal and sheathed thermocouple components of the basic structure, and with various fixed device. Armored thermocouple type insulation shell and then two.

    Three, main features:

    The thermal response time, reduce the dynamic error;

    Flexible installation;

    Large measuring range;

    High mechanical strength, good pressure resistance;

    Four, technical parameters:

    Product executive standard

    IEC584

    IEC1515

    GB/T16839-1997

    JB/T5582-91

    Nominal pressure thermocouple: generally refers to the static outer protective tube can withstand working temperature and pressure rupture.

    Thermocouple: minimum insertion depth should be not less than 8-10 times the diameter of the protective sleeve (Frederick product exception)

    Insulation resistance: when the ambient air temperature is 15-35 DEG C, relative humidity is less than 80% when the insulation resistance is more than 5 megohm (voltage 100V). With the splash proof junction box of the thermocouple, when the relative temperature is 93 + 3 DEG C, the insulation resistance of more than 500 billion euro (voltage 100V)

    The insulation resistance of high temperature thermocouples under high temperature, the thermal electrode (including double type) and the insulation resistance between protection tube and double heat electrode (per meter) should be greater than the value specified under the table.

    Armored thermocouple at ambient temperature for 20 + 15 ~ C, the relative humidity is not more than 80%, the test voltage is 500 + 50V (DC) insulation >1000 resistor between.M electrode and outer tube.

    Five, Selection code:


    ModelExplain
    W
    Temperature meter (Zhongwei control)

    R
    Thermocouple

    PThe temperature sensing element materialP 10- platinum rhodium

    MNickel chromium nickel silicon - silicon

    NNickel chromium nickel silicon

    ENickel chromium - nickel copper

    CCopper - copper nickel

    FIron - nickel copper

    K
    Armoured type

    nothingWire logSingle

    TwoDouble branch

    OneinstallfixedformNo fixed device

    TwoThe fixed clip sleeve thread

    ThreeThe movable clamping sleeve thread

    FourThe fixed clip sleeve flange

    FiveThe movable clamping sleeve flange

    TwoConnection boxBlowout type

    ThreeWaterproof type

    SixRound type

    SevenFlat type

    EightHandle type

    NineThe compensation wire type

    OneThe working end formInsulation type
    FourMAdditional chargeThe formContact block

    GHoop type package

    Six, Design selection and ordering information:
    Please provide the indexing number, precision grade, fixed form, protection material, length or depth of insertion tube (protective tube length L=l+150, special insertion depth and protection tube material can be ordered according to the agreement). 
    Customer service service commitment:
    1, my company sold thermocouple series products in quality problems arise within twelve months, responsible for free maintenance.
    2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
    3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
    4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
    5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


    Browse: