  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
    0517-86918678
    Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
    Tel:0517-86918678
    Fax:0517-86918679
    Email:zhongweick@https://msxpack.com
    Post Encoding:211600

    Explosion-proof thermal resistance

    6防爆(bao)型熱電阻(zu)(灋蘭式)01.png
    • 6防爆型熱電阻(灋蘭式)01.png
    WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal r…

    Description:

    Productoverview:

    WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal resistance is basically the same, the difference is, flameproof or intrinsically safe explosion-proof junction box products (shell) special structure is adopted in the design, wiring box with high strength Aluminum Alloy die casting, and has sufficient internal space, wall thickness and mechanical strength, thermal stability of rubber seal the rings are in line with national standards. So, when the explosive mixed gases inside the enclosure when the explosion occurred, the internal pressure will not destroy the junction box, and the resulting heat is not the outward diffusion of detonation.

    Two, work principle:
    WZP-240 series Explosion-proof thermal resistance The gap explosion-proof junction box component design principle, with sufficient strength, all can produce a spark, arc and dangerous temperature components are sealed in a box cavity, when the cavity when the explosion occurred, the joint gap flameout and cooling, so that the explosion flame and temperature transmission to the outside of the cavity, thereby temperature measurement.
    Three, application:
    WZP-240 series Explosion-proof thermal resistance Usually, record and display instruments using instruments, electronic computing and other supporting. Direct measurement of hydrocarbons in the production site and other explosives -200 ~ C~500 ~ C range of liquid, steam and gas and solid surface temperature.
    Four, main features:
    1, various forms of explosion-proof, explosion-proof performance;
    2, large measuring range;
    3, high mechanical strength, good pressure resistance.
    4, a spring type temperature sensing element, good seismic performance;
    Five, technical parameters:
    Product executive standard
    IEC751
    JB/T18622-1997
    JB/T8623-1997
    JB/T5518-91
    Insulation resistance at room temperature
    Heat resistance at ambient temperature is 15 to 35 DEG C, relative humidity is less than 80%, the test voltage is 10 - 100V (DC) >100M. The insulation resistance between electrode and outer tube.

    Six, installation method:
    1, first of all should measure the good thermal resistance thread thread or flange size, supporting flange or thread processing base.
    2, according to the size of the base flange or threaded hole in the pipe, to be measured.
    3, the flange or the screw tooth of the welding. The flange or thread is inserted has opened hole in the flange or threaded seat base and pipeline measured welding.
    4, the screw base thermal resistance with bolts or threaded in has been welded.
    5, in accordance with the wiring diagram of the terminal box thermal resistance grounding line, and the display instrument is connected on the dial corresponding. Connection box can not contact with the wall of the measured medium pipeline, ensure the junction box temperature not exceeding 100 DEG C. Outlet hole junction box should prevent due to poor sealing water vapor, dust deposition caused by short circuit terminal.

    Seven, measurement range and tolerance:

    Model

    Graduation

    The temperature range of C DEG

    Precision grade

    Tolerance

    WZP240

    Pt100

    -200-+500

    A

    (0.15+0.002 + LTL)

    WZC240

    Pt100

    -200-+500

    B

    (0.30+0.005ltl).

    Eight, selection table:

    Code

    WZ - - - - - - - - - - - - - / - armored thermal resistance

    W

    Temperature meter (Zhongwei control)


    Code


    Z

    Heat resistance


    Code

    The temperature measuring element

    P

    Pt100 Pt1000 (the order required)

    C

    Cu50


    Code


    K

    Armoured type (assembled the symbol)


    Code



    Single

    Two

    Double branch


    Code

    Installation assembly (armoured)

    Zero

    No protection tube

    One

    No fixed device

    Two

    Fixed thread

    Three

    Movable flange

    Four

    Fixed flange

    Five

    90 degree angle flange

    Six

    Fixed thread taper

    Code

    Installation of armor type

    One

    No fixed device

    Two

    The fixed clip sleeve thread

    Three

    Flecible thread

    Four

    The fixed clip sleeve flange

    Five

    The movable ferrule flange


    Code

    Connection box

    Zero

    Simple type

    One

    Ordinary type

    Two

    Splash proof (waterproof type substitution)

    Three

    Waterproof type

    Four

    Explosion proof type

    Six

    Socket type

    Seven

    With the connecting wire type


    Code

    Armoured armoured body diameter

    Three

    Phi 3mm

    Four

    Phi 4mm

    Five

    Phi 5mm

    Six

    Phi 6mm

    Eight

    Phi 8mm

    Code

    The diameter of the outer protection tube assembly (full armor)

    Zero

    Phi 16mm

    One

    Phi 12mm

    Heat resistance A By ordering protocol.

    Note: the connector form, convenient installation, suitable for measuring -200-450 Liquid, gas and solid surface temperature range.

    The design and selection of notes:
    1, model;
    2, division no.;
    3, precision grade;
    4, fixed form;
    5, the length or depth of insertion.
    Customer service service commitment:
    1, my company sold Zhongwei Thermal resistance series The product within twelve months of quality problems, responsible for free maintenance.
    2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
    3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
    4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
    5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


    Browse:
    Return To The Top

    分亯到:

    UmpmXjavascript:void();

    <strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>