    Automatic Verification and Calibration System of Temperature

    溫度自(zi)動檢定校(xiao)驗係統(tong).jpg
    • 溫度自動檢定校驗係統.jpg
    The automatic temperature calibration device is a new generation product developed in Windows enviro…

    Description:

    Productoverview:
    ZW-Y8001 series Automatic calibration system of temperature Is in the Windows environment, full use of language to develop a new generation of product under Windows environment, system is based on the microcomputer as the core, with high precision imported digital multimeter, and a low potential scanning switch, the power regulator is composed of measurement and control system.The operator can be in Chinese Win98/ Win2000/ WinMe operating system conveniently with the mouse of the whole process of operation, the microcomputer system for real-time display calibration furnace (or oil tank, water), temperature control curve and test time parameters.
    Second, the function of the system.
    ZW-Y8001 series Automatic calibration system of temperature According to the national metrological verification data processing, and can print various record form and verification certificate, but also keep the original records for future reference.The system has realized all automation, thermocouple and thermal resistance test process: automatic temperature control, automatic calibration, automatic data processing, automatic print verification results.The labor intensity is greatly reduced, and improved the quality of verification work.The device also provides certification program of the system and data file management procedures for certification and verification of the system operator archiving, retrieval and query provides a convenient.
    Three, system execution rules:
    1, JJG141 - 88, 10 - Industrial Platinum Rhodium 13 Platinum Rhodium Platinum thermocouple;
    2, JJG668 - 1997, 10 - Industrial Platinum Rhodium 13 Platinum Rhodium Platinum thermocouple verification regulation of short;
    3, JJG29082 industrial platinum 30 rhodium 6 thermocouple verification regulation;
    Verification regulation of base metal thermocouple with 4, JJG3511996 industry;
    5, JJG36884 industrial copper constantan thermocouple verification regulation;
    6, JJG229 - 1998 industrial platinum copper heat resistance test procedures.
    Fourth, the main features:
    1. high precision and high resolution accuracy: 0.005% resolution 0.1MV;
    2. high degree of automation: automatic temperature control, automatic calibration, automatic data processing, automatic print verification record and verification certificate;
    3. advanced methods of operation: the use of Windows software, Win98/WinXP system can operate with the mouse;
    4. visual display: display in the verification process of real-time display of temperature (or oil tank, water tank and so on) the temperature curve, cold temperature, temperature control thermocouple MV values (resistance) and test time;
    5. complete function, flexible configuration: the test of various of thermocouples and heat resistance, has a variety of temperature compensation and multiple table interface driver: detection of temperature can be set arbitrarily, the system has manual / automatic switching function, the whole operation button;
    6. temperature control of high precision, short time verification: the temperature control algorithm, temperature to ensure the verification process change rate is less than 0.2 Deg. C /min, C < 0.04 /10min oil tank;
    7. high degree of standardization, the report specification: verification data processing, verification record verification certificate in accordance with the regulations of national current standards and metrology;
    8. has a system test function: the system is equipped with the thermocouple calibration device itself certification test module, automatic verification device of thermocouple and thermal resistance of the total uncertainty, repeatability error and temperature field test furnace and oil tank for testing and sorting to print out the certification report;
    9. data management system has functions: data file management function, can store, archive and retrieve the verification report;
    10. perfect protection measures: the system of digital meter, main control box, thyristor regulator, special interface and wire connection to self check;
    11. the hardware design is reasonable, advanced production technology, the key parts are imported components, controllable silicon regulator, can provide three way adjustment function output, provide convenient for different controlling object conversion.
    Five, temperature range:
    1, the thermocouple 300 to 1100 DEG c;
    2, the thermal resistance of 0~300 DEG C.
    Six, detection of thermal resistance type:
    1, work with S, K, thermocouple: E, J, N, EA2, B, T (U, L) type;
    2, work with heat resistance: Cu50, Cu100, Pt10, Pt100 and other nine models.
    Seventh, the detection accuracy:
    1, voltage measurement accuracy is better than 0.02%, the resolution of 0.1 V;
    2, resistance measurement accuracy is better than 0.02%, the resolution of 0.1M;
    3, the measuring channel parasitic potential is less than or equal to 0.4 V;
    4, the maximum heating rate constant temperature equipment: tube calibration furnace 30 /min < C > 2 C /min oil tank.
    Eight, the temperature control accuracy:
    1, tube calibration furnace and deviation less than 5 DEG C preset detection point;
    2, oil (water) tank temperature deviates from the preset point less than 1.5 DEG c;
    3, test measurement (tank), furnace temperature stability;
    4, tube calibration furnace temperature is not higher than 0.2 DEG /min and less than or equal to 0.5 DEG /10min;
    5, the oil tank temperature is not higher than 0.02 DEG /min and less than or equal to 0.04 DEG /10min.
    6, the cold end temperature automatic compensation;
    7, when the cold end temperature at 20 - 10 DEG C range, the compensation error is less than 0.2 DEG c;
    8, each test point detection time is about 1.5min;
    9, uncertainty of the calibration results (including standard error, the confidence probability is 99.8%);
    Thermocouple: less than or equal to 1.2 DEG C, the repeatability error is not higher than 0.2 DEG (600 DEG C);
    Heat resistance: less than or equal to 0.05 DEG C, the repeatability error is not higher than 0.012 DEG (100 DEG C).
    Number nine, system:
    1: 6, the thermocouple (including standard thermocouple 1);
    2, thermal resistance: 6 (including 1 standard thermal resistance);
    3, test data processing strictly according to the standard of current national metrological verification regulations and requirements;
    4, anti disturbance performance: String = 46db = 100dB; common mode;
    5, the working environment: 0~40 degrees Celsius temperature, when the temperature exceeds the (20 + 5) C should be revised by temperature.The relative humidity is lower than 70%;
    6, power supply: 220V + 10%AC, 50Hz. and good grounding (earthing resistance less than 5 ohm);
    7, power consumption: tube calibration furnace: 2KW; oil tank (water): 4KW;
    8, detection system: 500W (including computer system).
    Ten and other ancillary equipment:
    The verification of the furnace, oil (water), see "JJG35-96 JJG229-98 slot index", less than 400mm long thermocouple testing furnace should choose short.
    1, ice machine;
    2, a set of special software;
    3, tube calibration furnace;
    4, special I communication cable three;
    5, an oil tank (tank) (order matching);
    6, freezing device (a ice bottle (attached) tube seven);
    7, the cold end of a temperature sensor with automatic compensation;
    8, I/O, IEEE488 special Luca a;
    9, two standard thermocouple (type S) a (order matching);
    10, two standard platinum resistance thermometer (an order matching);
    11, a thyristor voltage regulator (three output: test furnace, oil tank, water tank);
    12, a host (61/2 digital multimeter, 10 x 4 scanner, I/O interface);
    13, a set of computer (including host, keyboard, mouse, VGA color display, printer etc.).
    Eleven, system configuration list:

    microcomputer

    system

    Name

    Company

    Number

    prepare notes

    Host

    set

    One

    To configureP4 3.2Above2G 360GLight, drive, control board(Assembled)

    Monitor

    platform

    One

    SeventeenInch flat screen LCD

    Laser printer

    platform

    One

    CANON

    Communication cable

    root

    Two


    Multifunctional power socket

    only

    One


    The data acquisition control system

    The main control and power control box

    platform

    One

    Full automatic SCR power protection device, multi channel computer automatic scanning switch system etc.

    Measurement and control cable

    set

    One

    The high temperature of five core shielded cable,Twelvegroup* 8M

    A multimeter

    platform

    One

    KEITHLEY 6 1/2position(Imported)

    Temperature sensor

    only

    One

    Cold end compensation

    Optional

    parts

    Tube calibration furnace

    platform

    One

    There are larger than the geometric center axis60mm,OneC the uniform temperature field.The highest temperature in the furnace+ 20mmIn the temperature gradientLess than or equal to 0.4C/cmThe temperature range:Zero-One thousand and one hundredC

    Thermostatic oil bath

    platform

    One

    room temperature-5-Three hundredC automatic thermostat, stainless steel inner shell, temperature fluctuationZero point zero oneC/30minTemperature uniformity.Less than or equal to 0.01C

    ice bottle

    only

    One


    Freezer

    platform

    One


    Ice machine

    platform

    One


    Operation table

    platform

    One

    1600 x 840 x 1300

    Two standard

    rtd

    branch

    One

    WZPB-Two

    Two standard platinum10-Platinum thermocouple

    branch

    One

    WRPB-Two

    High precision platinum resistance test tank

    platform

    One

    -5~Three hundredC automatic thermostat, stainless steel inner shell, temperature fluctuationZero point zero oneC/30minTemperature uniformity.Less than or equal to 0.01C.Such as the selection of modified groove can replace the oil tank, water tank, ice bottle, ice machine, freezer

    Note: the automatic check system according to the national metrological verification data processing, and can print various record form and verification certificate, but also keep the original records for future reference.