    Rosemount 3051L Flanged Installed Level Transmitter

    儸斯矇特3051L灋蘭(lan)安裝液位變送器.jpg
    • 儸斯矇特3051L灋蘭安裝(zhuang)液(ye)位變送(song)器.jpg
    Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier desig…

    Description:

    Productoverview:
    Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier design to make the packaging becomes small, and the miniaturization of the membrane structure and the flange of the box, this type of weight dropped to half of the original type. ASIC design not only reduces the number of parts, but also improve the reliability of the amplifier.
    Two, work principle:
    When working, the high and low pressure side of the diaphragm and the filled liquid transmit the process pressure to the filling liquid filled liquid, then transmits the pressure to the center of the sensing diaphragm sensor. The sensing membrane is a elastic element of tension, compression and displacement with the change (for GP gauge transmitter, atmospheric pressure as applied in the low voltage side of the sensing membrane.). The AP absolute pressure transmitter, low voltage side always maintain a reference pressure. The sensing membrane Zui large displacement is 0.004 inches (0.1 mm), and the displacement is proportional to pressure. The capacitor plates on both sides of the diaphragm position detection sensor. The difference between the capacitance sensing diaphragm and capacitor plate is converted to the corresponding voltage or current, HART (high speed digital data highway addressable remote transmitter output signal).
    Third, widely used:
    For the measurement of gas, liquid and vapor pressure, and then turn it into a current signal output 4-20mADC. Can HART375, 475 hand operator to communicate with each other, setting and monitoring through them.
    Fourth, the main features:
    1, 5 years of continuous work without adjustment;
    2, the temperature effect is negligible;
    Influence of static pressure can be ignored;
    3, one-way impact: 100 thousand consecutive unidirectional overvoltage overvoltage after the experiment affect the amount of less than 0.03%;
    4, improve the self diagnosis function;
    5, small, lightweight (standard 3.9kg);
    6, static effects are neglected:
    When a static pressure (pressure), resonant beam deformation two shape, size and material identical to the same, so the frequency change is consistent, so the deviation automatically cleared (figure similar formula and temperature influence).
    7, excellent properties of unidirectional overvoltage:
    The liquid membrane and the membrane using corrugated box body processing technology of the original, so that the external pressure increases to a certain value, the film can fully contact with the body, silicone oil is transferred to the sensor pressure no longer increase with the increase of external force, so as to achieve the protective effect on sensor.
    Five, technical parameters:
    The 1. level measurement accuracy of 0.075%;
    2. calibration range from 0.25inH2O to 8310inH2O;
    3. flat film chip, 2-, 4-, and inch extend type diaphragm;
    4. kinds of filling liquid optional, can meet the requirements of different applications;
    5. clever and lightweight, easy installation and maintenance;
    6. liquid material: 316L stainless steel, Hastelloy, tantalum.
    Six, selection table:

    Model

    Product name

    3051L

    Flange mounted liquid level transmitter

    Code

    Pressure range (range /zui Small range)

    Two

    -250 to 250inH Two O/2.5H Two O (-62.2KPa to 62.2KPa/0.62KPa)

    Three

    -1000 to 1000inH Two O/10H Two O (-248KPa to 248KPa/2.5KPa)

    Four

    -8310 to 8310inH Two O/83.1H Two O (-2070KPa to 2070KPa/20.7KPa)

    Code

    output

    A

    4-20mA Based on a HART Digital signal protocol

    M

    Low power consumption, 1-5VDC Based on a HART Digital signal protocol ( 0.8-3.2VDC Output option code C2 )

    F

    FF Bus

    W

    PROFIBUS

    Code

    Diaphragm size

    Material Science

    Extended length

    Notes

    G0

    2in./DN 50

    316L SST

    Only the plane type

    Extension with diameterEighty The Conduit

    Size. Of Forty Pipe size,

    Please consult factory.

    H0

    2in./DN 50

    Hastelloy C-276

    Only the plane type

    J0

    2in./DN 50

    tantalum

    Only the plane type

    A0

    3in./DN 80

    316L SST

    Plane type

    A2

    3in./DN 80

    316L SST

    2in./50mm

    A4

    3in./DN 80

    316L SST

    4in./100mm

    A6

    3in./DN 80

    316L SST

    6in./150mm

    B0

    4in./DN 100

    316L SST

    Plane type

    B2

    4in./DN 100

    316L SST

    2in./50mm

    B4

    4in./DN 100

    316L SST

    4in./100mm

    B6

    4in./DN 100

    316L SST

    6in./150mm

    C0

    3in./DN 80

    Hastelloy C-276

    Plane type

    C2

    3in./DN 80

    Hastelloy C-276

    2in./50mm

    C4

    3in./DN 80

    Hastelloy C-276

    4in./100mm

    C6

    3in./DN 80

    Hastelloy C-276

    6in./150mm

    D0

    4in./DN 100

    Hastelloy C-276

    Plane type

    D2

    4in./DN 100

    Hastelloy C-276

    2in./50mm

    D4

    4in./DN 100

    Hastelloy C-276

    4in./100mm

    D6

    4in./DN 100

    Hastelloy C-276

    6in./150mm

    E0

    3in./DN 80

    tantalum

    Only the plane type

    F0

    4in./DN 100

    tantalum

    Only the plane type


    Code

    Installation flange size

    Rating

    Material Science

    Applicable to high voltage side of diaphragm size

    M

    2in.

    One hundred and fifty level

    carbon steel

    2 in./DN50

    A

    3in.

    One hundred and fifty level

    carbon steel

    3 in./DN80

    B

    4in.

    One hundred and fifty level

    carbon steel

    4 in./DN100

    N

    2in.

    Three hundredlevel

    carbon steel

    2 in./DN50

    C

    3in.

    Three hundredlevel

    carbon steel

    3 in./DN80

    D

    4in.

    Three hundredlevel

    carbon steel

    4 in./DN100

    P

    2in

    Six hundredlevel

    carbon steel

    2 in./DN50

    E

    3in.

    Six hundredlevel

    carbon steel

    3 in./DN80

    X

    2in.

    One hundred and fifty level

    SST

    2 in./DN50

    F

    3in.

    One hundred and fifty level

    SST

    3 in./DN80

    G

    4in.

    One hundred and fifty level

    SST

    4 in./DN100

    Y

    2in.

    Three hundredlevel

    SST

    2 in./DN50

    H

    3in.

    Three hundredlevel

    SST

    3 in./DN80

    J

    4in.

    Three hundredlevel

    SST

    4 in./DN100

    Z

    2in.

    Six hundredlevel

    SST

    2 in./DN50

    L

    3in.

    Six hundredlevel

    SST

    3 in./DN80

    Q

    DN 50

    PN 10-40

    carbon steel

    2 in./DN50

    R

    DN 80

    PN 40

    carbon steel

    3 in./DN80

    S

    DN 100

    PN 40

    carbon steel

    4 in./DN100

    V

    DN 100

    PN 10/16

    carbon steel

    4 in./DN100

    K

    DN 50

    PN 10-40

    SST

    2 in./DN50

    T

    DN 80

    PN 40

    SST

    3 in./DN80

    U

    DN 100

    PN 40

    SST

    4 in./DN100

    W

    DN 50

    PN 10/16

    SST

    4 in./DN100


    Code

    The process of oil filling -High pressure side

    Temperature limit

    A

    Syltherm XLT

    -75 to One hundred and fifty C (-102 to302 ~ F)

    C

    D.C.704 silicone oil

    Zero to Two hundred and five C (32 to401 degrees F)

    D

    D.C.200 silicone oil

    -45 to Two hundred and five C (-49 to401 degrees F)

    H

    Inert liquid

    -45 to One hundred and seventy-five C(-49 to 347 degrees F)

    G

    Glycerin and water

    -15 to Ninety-five C (5 to 203 degrees F)

    N

    Neobee M-200

    -15 to Two hundred and five C (5 to 401 degrees F)

    P

    Propylene glycol and water

    -15 to Ninety-five C (5 to 203 degrees F)


    Code

    option


    Header

    M (1)

    Linear meter, 0-100% scale

    M3 (1)

    The special calibration table, specify the range

    M4 (1)

    LCD Header, 0-100%

    M7 (1)

    LCD First, linear, special set


    Hazardous area certification

    E5

    The Canadian Standards Association (CSA) Flameproof certification

    I5 (2)

    Factory mutual (FM) Non flammable and safety certification

    K5

    Factory mutual (FM) Flameproof and intrinsically safe comprehensive certification

    C5 (3)

    Canada certification industry and Science ( Only Canada )

    C6 (2)

    I6 and E6 Combination, CSA Flameproof and intrinsically safe certification


    ( Requirement Zui High power supply voltage 42.4Vdc)

    K6

    CSA/CENELEC Flameproof and intrinsically safe certification

    EF (4)

    China NEPSI, GB Flameproof certification standard

    EF (2) (4)

    China NEPSI, GB Standard essential safety certification

    E4

    Japanese industrial standard (JIS) Flameproof certification

    E7

    The Standards Association of Australia (SAA) Flameproof certification

    E8

    CESI/CENELEC Flameproof certification

    I1 (2)

    BASEEFA The essence of security authentication

    I7 (2)

    The Standards Association of Australia (SAA) The essence of security authentication

    I8 (5)

    CESI/CENELEC The essence of security authentication

    N1 (2)

    BASEEFA N Type certification

    N7

    The Standards Association of Australia (SAA) Non flammable safety certification

    IC (2)

    SEV The essence of security authentication


    Other options

    W5

    copper O Ring type, used for vacuum occasions (non wetted parts)

    Q4

    Check data sheet

    Q8 (6)

    Material traceability, in accordance with EN 10204 3.1B

    L4

    316 SST Flange and bolt joints

    V1

    Inverting output

    V2

    4-20mV test signal

    V3

    20-100mV test signal

    Z1 (7)

    4- Line, 0-20mA output

    Z2 (7)

    4- Line, 0-16mA output

    Z3 (7)

    4- Line, 0-10mA output

    F_

    From table flush connection options in selecting a set of code

    Seven typical models:

    3051L2AG0RD21AAK5M5Q4
    3051L2AH0KD21AAM5
    3051L3AA0FD21AB



    Browse:
    Return To The Top

    分亯(xiang)到:

    tFHcXjavascript:void();

    <strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>