  • Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
    0517-86918678
    Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
    Tel:0517-86918678
    Fax:0517-86918679
    Email:zhongweick@https://msxpack.com
    Post Encoding:211600

    High Temperature Compensation Wire

    高溫補償導線.jpg
    • 高溫補償導(dao)線.jpg
    High temperature compensation wire is suitable for temperature control system of energy, metallurgy,…

    Description:

    A brief introduction, conductor:
    Temperature compensation wireThe effect is to extend the thermode that cold end of thermocouple temperature measurement system and mobile display instrument is connected.High temperature thermocouple compensation wire insulation layer and protective layer according to the environmental requirements of the selected material is not the same, PVC sheath material, fluorine plastic, low smoke and low halogen PVC and alkali free glass wire several imported high-quality fluorocarbon can be high temperature of 260 DEG C, and the continuous extrusion process, make the product has excellent acid resistance, alkali resistance, and flame extension performance, can be used for a long time in oil.
    Temperature compensation wireThe use of temperature in - 60 - 260 C, which belongs to the contemporary domestic advanced level.Series of products are mainly used in various types of temperature measuring device, according to the variety of products is divided into SC, KC, KX, EX, JX, TX, NC.
    Two, the implementation of standards: GB/T4989/94 equivalent to IEC584.3,
    Three, use range:
    Temperature compensation wireApplicable to energy, metallurgy, petroleum, chemical and other industrial enterprises and scientific research departments, the temperature control system.For the connection between the cold end temperature measuring instrument and temperature measuring instrument.Heat type imported fluorine plastic insulated and sheathed with excellent heat resistance, waterproof, anti-corrosion, anti acid, chemical resistance, resistance to abrasion, aging and combustion performance.Use temperature of -60 to 260 DEG C, is the international advanced level.
    Three, the conditions of use:
    (1): highest working temperature: heat with 200 degrees and 260 degrees two;
    General: a maximum of 70 degrees and 105 degrees two.
    (2) the lowest ambient temperature: fluorine plastic insulated and sheathed cable laying: -60 C -20 C non fixed installation;
    PVC insulated and sheathed cable laying: -40 C -15 C non fixed installation.
    (3) the minimum bending radius: PVC insulated and sheathed cable non armored cable is not less than 6 times of cable diameter, 10 times of fluoroplastic insulation and sheath for non armored cable is not less than the diameter of the cable, not less than 12 times of cable diameter for armored cable.
    Four,Temperature compensation wireThe use of characteristics:

    type

    The minimum bending radius

    The lowest temperature

    Maximum temperature

    Unarmored

    Armoured

    Fixed installation

    Non fixed installation

    General type
    There are 105 types of ""
    There are 90 types of ""
    High temperature type

    6 times of the cable diameter
    10 times of the cable diameter

    12 times of the cable diameter

    C = -40

    C = -60
     

    C = -15

    C = -20
     

    Less than or equal to 70 DEG C
    Less than or equal to 105 DEG C
    Less than or equal to 90 DEG C
    Less than or equal to 250 DEG C

    Five, product code and meaning:

    project

    Code

    Code meaning

    project

    Code

    Code meaning

    Model

    SC

    Thermocouple compensation wire, S index

    Heat resistant grade

    Seventy

    The highest temperature is 70 DEG C

    RC

    Thermocouple compensation wire, R index

    One hundred and five

    The highest temperature is 105 DEG C

    NC

    Thermocouple compensation wire, N index

    Two hundred

    The highest temperature is 200 DEG C

    NX

    Thermocouple compensation wire, N index

    Two hundred and fifty

    The highest temperature is 250 DEG C

    KCA
    KCB

    Thermocouple compensation wire, K index

    Insulating materials

    V

    polyvinyl chloride

    KX

    Thermocouple compensation wire, K index

    Y

    polyethylene

    EX

    Thermocouple compensation wire, E index

    B

    polypropylene

    JX

    Thermocouple compensation wire, J index

    F4

    Teflon

    T

    Thermocouple compensation wire, T index

    F46

    Poly perchloro ethylene propylene

    Series code

    ZR

    Flame retardant cable

    Jacket material

    V

    polyvinyl chloride

    IA

    Intrinsically safe cable

    B

    glass fibre

    The use of classification

    G

    For general use

    F4

    Teflon

    H

    heat resistant

    F46

    Poly perchloro ethylene propylene

    Precision grade

    S

    Precision

    Shielding material

    P

    Copper wire braid

    P1

    Tinned copper braid

    /

    Common grade

    P2

    Copper tape wrapped

    P3

    Aluminum / plastic composite film wrapping

    Specifications


    2 x conductor cross-sectional area mm2

    Conductor type


    Single conductor can be omitted

    R

    Stranded conductors

    Armored

    Twenty-two

    Steel tape

    Thirty-two

    Steel wire armoured

    Six, technical indicators:
    1 type alloy wire material and insulation color

    Compensation wire type

    Thermocouple

    Mark thermocouple

    Compensation lead wire

    The insulation layer of color

    Positive order

    The negative

    Positive order

    The negative

    SC

    10- Platinum Rhodium Platinum thermocouple

    S

    SPC (copper)

    SNC (Cu, Ni)

    red

    green

    RC

    13- platinum rhodium thermocouple

    R

    RPC (copper)

    RNC (Cu, Ni)

    red

    green

    KCA

    Nickel chromium nickel silicon thermocouple

    K

    KPCA (iron)

    KNCA (Cu, Ni)

    red

    blue

    KCB

    KPCB (copper)

    KNCB (Cu, Ni)

    red

    blue

    KX

    KPX (CR)

    KNX (Ni SI)

    red

    black

    NC

    Ni Cr Si Ni Si thermocouple

    N

    NPC (iron)

    NNC (Cu, Ni)

    red

    ash

    NX

    NPX (Ni Cr SI)

    NNX (Ni SI)

    red

    ash

    EX

    Nickel - copper nickel thermocouple

    E

    EPX (CR)

    ENX (Cu, Ni)

    red

    Brown

    JX

    The iron - copper nickel thermocouple

    J

    JPX (iron)

    JNX (Cu, Ni)

    red

    purple

    TX

    Copper - copper nickel thermocouple

    T

    TPX (copper)

    TNX (Cu, Ni)

    red

    white

    2, the use of protective layer of color classification

    The use of classification

    Precision grade and sign

    Jacket color

    Common grade

    Precision

    Common grade

    Precision

    For general use

    G

    /

    S

    black

    gray

    heat resistant

    H

    /

    S

    black

    yellow

    Seven, delivery requirements:
    According to both agreements, the length of measurement error is about 0.5%.
    Eight, ordering:
    In order to indicate the product name, type, number, temperature rating, shielding type, quantity etc..


    Browse:
    Return To The Top

    分亯到(dao):

    rfdvZjavascript:void();

    <strike id="bTrg"></strike>

  • <option id="bTrg"></option>

    <abbr id="bTrg"><td></td></abbr>
  • <p id="bTrg"></p>

    <dl id="bTrg"></dl>