    Low smoke zero halogen flame retardant control cable

    低煙無滷阻燃控製電纜.jpg
    • 低煙無滷阻燃控製電(dian)纜.jpg
    Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 7…

    Description:

    An overview, cables:
    Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
    Second, the production of standard:
    Low smoke zero halogen flame retardant control cable to the enterprise standard and reference to GB9330-88 this product is suitable for use in ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
    Three control cables, low smoke zero halogen flame retardant technology performance:
    The product reference articles IEC227, IEC1034, IEC332 international standard design
    Four control cables, low smoke zero halogen flame retardant performance requirements:
    1, into A bundle of burning A or B, (coking section height) : 2.5 m or less.
    The distance of 2, secondary (without burning) : 50 mm or higher;
    3, smoke degree (minimum light transmittance) 60% or higher;
    4, HCL content acuities were 0.5 mg/g.
    Five, the model name:

    model

    The name of the cable

    KVV

    Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

    KVVP

    Copper low smoke zero halogen polyolefin insulated and sheathed woven block flame-retardant control cable

    KVVP2

    Copper low smoke zero halogen polyolefin insulated and sheathed copper tape screened flame-retardant control cable

    KVV22

    Copper low smoke zero halogen polyolefin insulation and sheath steel tape armoured flame-retardant control cable

    KVVR

    Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

    KVVRP

    Copper low smoke zero halogen polyolefin insulated and sheathed textile block flame-retardant control cable

    KVVP2-22

    Copper low smoke zero halogen polyolefin insulated and sheathed copper belt BingBiGang belt sheathed flame-retardant control cable

    KYJY

    Copper core with cross-linked polyethylene insulation polyolefin sheath low smoke zero halogen flame retardant control cable

    KYJYP

    Cross-linked polyethylene insulating tape armored low smoke zero halogen (B or C) A kind of flame retardant power cable

    KYJYP2

    Communication polyethylene insulated fine steel wire armoured low smoke zero halogen (B or C) A kind of flame retardant power cable

    KYJYP3

    Copper core with cross-linked polyethylene insulation polyolefin sheath aluminum-plastic composite belt shielding low smoke zero halogen flame retardant control cable

    KYJY23

    Copper core with cross-linked polyethylene insulation polyolefin sheath steel tape armoured low smoke zero halogen flame retardant control cable

    KYJYP2/23

    Copper core with cross-linked polyethylene insulation polyolefin sheath copper tape BingBiGang tape armored low smoke zero halogen flame retardant control cable

    KYJYP3/23

    Copper core with cross-linked polyethylene insulation polyolefin sheath with lu: su composite BingBiGang armoring low smoke zero halogen flame retardant control cable

    "WDZ" : it means low smoke zero halogen flame retardant
    Six, cable specifications:

    model

    Conductor nominal section (was)

    0.5

    0.75

    1.0

    1.5

    2.5

    4

    6

    10

    some

    KVV
    KVVP

    -

    2 ~ 61

    2 ~ 14

    2 ~ 10

    KVV2

    -

    4-61

    4 ~ 14

    4 ~ 10

    KVV22 
    KVVP2-22

    -

    7 ~ 61

    4-61

    4 ~ 14

    4 ~ 10

    KVVR

    -

    4-61

    -

    -

    KVVRP

    -

    4-61

    4 ~ 48

    -

    -

    Note: recommend some series for: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 44, 48 and 52 and 61 core.
    Seven, delivery requirements:
    1, into a circle of 100 m, a dish should be greater than 100 m;
    2, according to the supply and demand both sides agreement to allow any length of delivery, the length of the measurement error of plus or minus 0.5%.